multi-level security arming
Multi-Level Security Arming is a feature that allows you to select which of the security system's inputs or sensors
will be active and which will be bypassed at the time that the system is armed. (See
Table of Zones
section in
this guide.) Pressing the arm button (only on a Expanded Configuration transmitter) again within five seconds
of arming the security system will activate the Multi-Level Security Arming feature. Each time the arm button is
pressed again, a different security level is selected. The different security levels can be selected as follows:
■
Pressing the arm button once: The siren chirps once. The system is armed.
■
Pressing the arm button twice within five seconds: The siren chirps twice followed by a long chirp. Zone Two is
now bypassed.
■
Pressing the arm button a third time within five seconds: The siren chirps three times followed by a long
chirp. Zone Four is now bypassed.
■
Pressing the arm button a fourth time within five seconds: The siren chirps four times followed by a long
chirp. Zones Two and Four are now bypassed.
■
Pressing the arm button a fifth time within five seconds: The siren chirps five times followed by a long chirp.
All input zones, except the ignition, are now bypassed.
NOTE:
Multi-Level Security Arming only applies to a single arming cycle. Once the system is disarmed
and then re-armed, all the zones will be active again.
table of zones
When using the diagnostic functions, use the Table of Zones to see which input has triggered the system. It is
also helpful in deciding which input to use when connecting optional sensors and switches.
ZONE NO.
TRIGGER TYPE
INPUT DESCRIPTION
1
Instant
H1/6 BLUE wire. Connect to optional hood/trunk pins.
2
On-board shock sensor
Heavy impact detected by the on-board shock sensor.
3
Two-stage, progresses from
Door switch circuit. H1/5 GREEN or H1/7 VIOLET.
warning to full alarm
4
Multiplexed Input
BLUE and GREEN wires of optional sensor plug. Inputs
shorter than 0.8 seconds will trigger a Warn Away response,
while inputs longer than 0.8 seconds will instantly trigger
a full alarm sequence and report Zone 4.
5
Two-stage (similar to doors)
Ignition input. H1/9 YELLOW.
NOTE:
The Warn Away
®
response does not report on the LED.