MASTER AND LIMITED USER FUNCTIONS
Test Mode
Enter
Setting the Panel
Enter
(User Code)
and then
or
for set required.
Refer to the Zone Programming Status Label to see how each set was configured by the
installation engineer.
This function performs a number of tests which are listed below. The next test is selected by
pressing any numeric key.
Test
1)
All LEDs are switched on except the fault LED.
2)
The strobe is switched on.
Setting the Panel when the Mains Fails
3)
The bell is switched on.
4)
The internal sounder is switched on.
Under normal operation the panel will indicate a fault condition if the AC supply is
disconnected. It will still be possible to Set and Unset the panel during a mains fail only if
allowed by the engineer, and no further action is required. Full functionality of the panel is
available during a mains failure.
To exit test mode press the
key again.
Walk Test Mode
Silent Setting of the Panel
Enter
followed by
the master code and the set option, either
-
-
or
.
Enter
and then
or
for set required.
A dual tone will be heard on acceptance of the command, and another dual tone will be heard
when the panel is set.
When the walk test mode is enabled the ‘chime’ LED will flash. If the panel is then set each
active zone will cause a chime when triggered. This enables all the zone configurations to be
walk tested individually. The walk test mode is cleared when the panel is unset.
Push to Set
Set the panel in any of the above methods. The panel will count down, but will not set until the
PTS button is pressed.
The numbers of any activated zones will be entered into the event log. Zones programmed
as Keyswitch zones when activated in walk test will not be entered in the event log.
Final Door Set
Changing Master and Limited User Codes
Set the panel in any of the above methods, the panel will count down but will not set until the
final exit door is opened then closed.
Master Code
Enter
followed by
Master User Code (factory set at 1 2 3 4)
Arm with Omits
If any zones are triggered whilst in ext mode a low pitched error tone will be heard, any faulty
zones will be displayed in the seven segment display. First check for any obvious reason for
these zones to have been activated.
Enter
Enter the new code twice, three tones will be heard on acceptance of each command, a
single low tone indicates programming not accepted.
This may simply be due to a monitored door or window being left open or a pet being left in a
protected area. If the fault cannot be rectified it is possible to omit faulty zones but this should
only be used as a last resort if the building is to be left unoccupied.
Master code cannot be deleted.
Example: Set panel,
Limited User Code
then:
If no error tone heard, exit via normal route.
Enter
followed by
Master User Code (factory set at 1 2 3 4)
or:
If error tone heard:
Enter:
Enter
to
then;
number(s) of zones to be omitted (1 to 8)
then:
Entry / Exit timer will start again.
Enter the new code twice, three tones will be heard on acceptance of each command, a
single low tone indicates programming not accepted.
then:
exit
building by normal route.
To delete a user code press the
key after
to
is entered.
6
RINS137-7 RINS137-7
3