2.3.2.  Series Connection: 

Before wiring the battery model, make sure all batteries are turned off. Follow the steps 
shown below for wiring. Then press any battery’s Power button one by one. 

 

Please Note: 

1.  The maximum number of series connections is limited to 2 pcs - 24V. 
2.  Each battery should have the same capacity and the same voltage. Otherwise it will 

affect subsequent use 

3.  Ensure that the voltage difference between the batteries should not exceed 0.2V 

before connection. If batteries do exceed 0.2V difference then all batteries will 
require a full charge so they are an equal voltage. 

4.  Connect all batteries in parallel (considering point 3 above) for 12-24 hours so that 

batteries are equalized before connecting in series 

5.  If one battery goes into protective mode, the whole system will shut down 

 

3. 

Installation Environment

 

 

 

Battery operating environment requirements are as follows: 

Working temperature: 

0

 - 50

  

Humidity: 

 

 

5% - 95%  

Altitude: 

 

 

4000m 

The site environment:  

Away from heat, no corrosive gas, no explosive gas, no 

damaging gas, no damaging insulation Conductive dust 
 

Содержание RV12100

Страница 1: ...ly during the installation process Any confusion please contact Pylontech immediately for advice and clarification Table of Contents 1 Introduction 2 1 1 Product features 2 1 2 Product appearance 2 1...

Страница 2: ...le configuration and high reliability Voltage platform 12V High C rate the output power reaches sustained 1C High safety lithium iron phosphate battery is safe and reliable High reliability interactiv...

Страница 3: ...arine use 2 Product Parameters 2 1 Battery Module Technical parameters No Item Value 1 Nominal capacity 100 Ah 2 Nominal voltage 12 8Vdc 3 Voltage range 10 14 8 Vdc 4 Recommend charge voltage 10 14 4...

Страница 4: ...lth will light up and 1 second later the battery output will be active Press the Power Button for 3 seconds to turn off the battery Turning the battery back on is locked out for 3 seconds Self check l...

Страница 5: ...State Soc Status SOC Remark Run ALM SOC4 SOC3 SOC2 SOC1 Turn off All off Idle 0 25 All SOC Light is solid 26 50 51 75 76 100 Charge 0 25 The SOC top one is flashing others are solid 26 50 51 75 76 100...

Страница 6: ...1 The number of Parallel connections is limited to 8 pieces 2 Ensure that the voltage difference between the batteries should not exceed 0 2V before connection If batteries do exceed 0 2V difference t...

Страница 7: ...en the batteries should not exceed 0 2V before connection If batteries do exceed 0 2V difference then all batteries will require a full charge so they are an equal voltage 4 Connect all batteries in p...

Страница 8: ...d heat Battery storage SOC 40 50 Long term storage before storage the SOC should be more than 80 and the battery should be periodically recharged every six months to the 80 SOC Our products come with...

Отзывы: