background image

 

RV12100

_

 

    

Master Instruments Pty Ltd 

 

Please refer to the table below for normal display state

: 

Indicator light description:  

 

 

Blue light solid 

 

 

Blue light flashing (2S flashing) 

 

 

Red light solid 

 

 

Red light flashing (2S flashing) 

State 

Soc 

Status 

SOC  

Remark 

★ 

Run 

★ 

ALM 

SOC4 

SOC3 

SOC2 

SOC1 

 

Turn off 

 

 

 

 

 

 

 

All off 

Idle 

0% 25% 

● 

 

 

 

 

● 

All SOC Light is 
solid 

26%-50% 

 

 

● 

● 

51%-75% 

 

● 

● 

● 

76%-100% 

● 

● 

● 

● 

Charge 

0%-25% 

● 

 

 

 

 

 

The SOC top 
one is flashing, 
others are solid 

26%-50% 

 

 

 

● 

51%-75% 

 

 

● 

● 

76%-100% 

 

● 

● 

● 

discharge 

100%-76% 

 

 

● 

● 

● 

● 

The Run light is 
flashing 

75%-51% 

 

● 

● 

● 

50%-26% 

 

 

● 

● 

25%-0% 

 

 

 

● 

Alarm 

Alarm 

 

 

 

 

According to SOC state

 

Automatically 
eliminated when 
value back to 
normal level 

Protect 

Protect 

 

 

 

Battery 

shutdown until 

value back to 

normal level 

Содержание RV12100

Страница 1: ...ly during the installation process Any confusion please contact Pylontech immediately for advice and clarification Table of Contents 1 Introduction 2 1 1 Product features 2 1 2 Product appearance 2 1...

Страница 2: ...le configuration and high reliability Voltage platform 12V High C rate the output power reaches sustained 1C High safety lithium iron phosphate battery is safe and reliable High reliability interactiv...

Страница 3: ...arine use 2 Product Parameters 2 1 Battery Module Technical parameters No Item Value 1 Nominal capacity 100 Ah 2 Nominal voltage 12 8Vdc 3 Voltage range 10 14 8 Vdc 4 Recommend charge voltage 10 14 4...

Страница 4: ...lth will light up and 1 second later the battery output will be active Press the Power Button for 3 seconds to turn off the battery Turning the battery back on is locked out for 3 seconds Self check l...

Страница 5: ...State Soc Status SOC Remark Run ALM SOC4 SOC3 SOC2 SOC1 Turn off All off Idle 0 25 All SOC Light is solid 26 50 51 75 76 100 Charge 0 25 The SOC top one is flashing others are solid 26 50 51 75 76 100...

Страница 6: ...1 The number of Parallel connections is limited to 8 pieces 2 Ensure that the voltage difference between the batteries should not exceed 0 2V before connection If batteries do exceed 0 2V difference t...

Страница 7: ...en the batteries should not exceed 0 2V before connection If batteries do exceed 0 2V difference then all batteries will require a full charge so they are an equal voltage 4 Connect all batteries in p...

Страница 8: ...d heat Battery storage SOC 40 50 Long term storage before storage the SOC should be more than 80 and the battery should be periodically recharged every six months to the 80 SOC Our products come with...

Отзывы: