4.1 Product Transportation requirements 

Prevent violent vibration, impact or extrusion,  

Do not expose to sun or rain, 

In the process of loading and unloading, the battery should be handled gently to prevent 
throwing, rolling and weight. 

4.2 Product Storage requirements 

Batteries should be stored in clean, dry and ventilated rooms where the ambient 
temperature is -20

 ~ 60

 and the relative humidity is no more than 85%. 

Battery should avoid contact with corrosive substances, should be far away from the 
source of fire and heat. 

Battery storage SOC: 40% ~ 50%. 

Long-term storage: before storage, the SOC should be more than 80%, and the battery 
should be periodically recharged every six months to the 80% SOC.  

 

*Our products come with guarantees that cannot be excluded under the Australian 
Consumer Law. You are entitled to a replacement or refund for a major failure and for 
compensation for any other reasonably foreseeable loss or damage. You are also entitled 
to have the goods repaired or replaced if the goods fail to be of acceptable quality and the 
failure does not amount to a major failure. The benefits under this warranty are in addition 
to other rights you may have at law. 

The warranty against defects is provided by the import agent Master Instruments Pty Ltd: 
13 Sheridan Close Milperra NSW 2214. 

Содержание RV12100

Страница 1: ...ly during the installation process Any confusion please contact Pylontech immediately for advice and clarification Table of Contents 1 Introduction 2 1 1 Product features 2 1 2 Product appearance 2 1...

Страница 2: ...le configuration and high reliability Voltage platform 12V High C rate the output power reaches sustained 1C High safety lithium iron phosphate battery is safe and reliable High reliability interactiv...

Страница 3: ...arine use 2 Product Parameters 2 1 Battery Module Technical parameters No Item Value 1 Nominal capacity 100 Ah 2 Nominal voltage 12 8Vdc 3 Voltage range 10 14 8 Vdc 4 Recommend charge voltage 10 14 4...

Страница 4: ...lth will light up and 1 second later the battery output will be active Press the Power Button for 3 seconds to turn off the battery Turning the battery back on is locked out for 3 seconds Self check l...

Страница 5: ...State Soc Status SOC Remark Run ALM SOC4 SOC3 SOC2 SOC1 Turn off All off Idle 0 25 All SOC Light is solid 26 50 51 75 76 100 Charge 0 25 The SOC top one is flashing others are solid 26 50 51 75 76 100...

Страница 6: ...1 The number of Parallel connections is limited to 8 pieces 2 Ensure that the voltage difference between the batteries should not exceed 0 2V before connection If batteries do exceed 0 2V difference t...

Страница 7: ...en the batteries should not exceed 0 2V before connection If batteries do exceed 0 2V difference then all batteries will require a full charge so they are an equal voltage 4 Connect all batteries in p...

Страница 8: ...d heat Battery storage SOC 40 50 Long term storage before storage the SOC should be more than 80 and the battery should be periodically recharged every six months to the 80 SOC Our products come with...

Отзывы: