background image

 

4.6 Memory 

The internal memory can hold up to 90 readings. 

1) Memory Review 

a)

 

With monitor power off, hold the 

M

button to enter the memory mode.   

b)

 

The unit will display the most recent 3 set of data average   

c)

 

When holding  the

M

button  the user  can  view  the data from the  most  recent  date to the 

oldest date. When holding the

S

button the user can view vice versa. 

Caution: Continuous holding the 

M

button will delete all the memory. 

2) Delete memory data 

a)

 

Enter into the memory mode. 

b)

 

Press and hold the memory button until the “---” displayed, all the memory data will be 

deleted 

c)

 

The unit will only delete the present set of memory data; the other set of memory data 

will not be affected. 

d)

 

The device is not capable of deleting a single data entry 

e)

 

Press the 

ON/OFF

  button exit the memory mode and turn off. 

 

5. Error Indication 

List of Error code. 

Error 

Cause 

How to correct 

Er 30 

Power on, cuff inflation rate is too 
low or main unit does not connect 
with the cuff. 

1

 

Reconnect  the  air  tube  connector 
with the main unit 

2

 

Cuff  or  bladder  leakage,  if 
necessary purchased a new one.   

3

 

Confirm  the  cuff  is  wrapped  up 
correctly  (ref  4),  retake  the 
measurement 

Er 2 

Weak Signal or cuff is too loose 

Cuff too loose

Confirm the cuff is 

wrapped up correctly

ref 4.2

retake the 

measurement 

Er 3 

Heavy shock during the 

measurement. 

Remain still, retake the measurement (ref 
4.1

 

Er 5 

Bad Signal

moving or talking 

during the measurement 

Remain still, retake the measurement (ref 
4.1

 

Er7 

Measurement abnormal. 

Please retake the measurement. 

Lo 

Low battery power, cannot inflate 

Change battery

ref 3.1

 

 

6. Trouble Shooting 

When the unit encounters malfunction during the use, refer to table below: 

Abnormal 

How to correct 

After  batteries  installation,  power 

1

  Check batteries polarity

 

Содержание PHBPB16TL

Страница 1: ...ant Noted 6 4 2 Fitting the cuff 6 4 3 Body posture during measurement 7 4 4 Take Measurement 7 4 5 Data Transmission 8 4 6 Memory 9 5 Error Indication 9 6 Trouble Shooting 9 7 Specification 10 8 Abou...

Страница 2: ...o vibration such as ambulances and emergency helicopters A location where there is gas or flame A location where there is water or steam A location where chemicals are stored A location where the unit...

Страница 3: ...h several trials of testing to ensure the measurement accuracy The end user should conduct a manufacturer recommended inspection and calibration annually Blood pressure measurements determined with th...

Страница 4: ...Cuff Type BF Applied Part Model PHBPB16TL Applicable Arm Circumference 8 6 to 14 inches Note Symbol for TYPE BF APPLIED PART Display...

Страница 5: ...r demonstration purpose It is possible these batteries will therefore not last for 200 measurements The battery life can be confirmed in the bottom right of the display If the low battery symbol is di...

Страница 6: ...at can raise blood pressure Try not to take your blood pressure if you are nervous or upset If you are nervous anxious or agitated your blood pressure will rise Rest for 5 10 minutes before taking a r...

Страница 7: ...ensure the measurement accuracy 4 3 Body posture during measurement Relax place the elbow on the desk with palm facing up cuff should be at the heart level Fig 9 The reading accuracy may be affected...

Страница 8: ...ic pressure is greater or equal to 90mmHg as abnormal The display will flash to remind the end user of the blood pressure abnormality If the device caused any discomfort during measurement or fail to...

Страница 9: ...e memory mode and turn off 5 Error Indication List of Error code Error Cause How to correct Er 30 Power on cuff inflation rate is too low or main unit does not connect with the cuff 1 Reconnect the ai...

Страница 10: ...during the day which also will affect by the human emotional and physical condition 2 Record the variance and consult to the doctor If the above suggestion doesn t remediable please dial Pyle Technic...

Страница 11: ...Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC s and mobile cellular telephones medical devices in use may be susceptible...

Страница 12: ...oltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Not applicable...

Страница 13: ...ions equipment and the EQUIPMENT or SYSTEM The EQUIPMENT or SYSTEM is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of th...

Страница 14: ...axed person and still have HBP Let s look at the facts about blood pressure so you can better understand how your body works and why it is smart to start protecting yourself now no matter what your bl...

Страница 15: ...morning blood pressure and this happens in 50 of the cases Patients with morning hypertension have a 78 more chance of stroke compared with 48 of other hypertensive patients without morning high bloo...

Страница 16: ...ymbol for manufacturer 0123 Symbol for CE Symbol for Follow operating instructions Symbol for TYPE BF APPLIED PART Symbol for electrical and electronic equipment IP21 Symbol for the IP classification...

Отзывы: