Do not use at extremely high temperature, high humidity, or high altitude. Use only within the 

required ambient conditions. 

 

Do not place heavy objects on the AC adapter cable, or allow the unit to sit on the cord. 

 

Do not plug in or unplug the AC adapter with wet hands. 

 

Do not drop or expose the device to heavy shock. 

 

Do not use the unit near large equipment that uses a switching relay for power ON/OFF. 

 

Remove the batteries if the unit will not use for a long time. 

 

Clinical testing has not been conducted on newborn infants and pregnant women. Do not use 

on newborn infants and pregnant women. 

 

The  blood  pressure  monitor  has  gone  through  several  trials  of  testing  to  ensure  the 

measurement  accuracy.  The  end  user  should  conduct  a  manufacturer  recommended 

inspection and calibration annually. 

 

Blood pressure measurements determined with the device are equivalent to those obtained by 

a trained observer using the cuff/stethoscope auscultatory method, within the limit prescribed 

by the American National Standard, Manual, electronic or automated sphygmomanometers. 

 

Keep  out  of  reach  of  infants,  small  children,  and  compromised  people  who  cannot  express 

their consent. 

 

This product is suitable for use to self- monitoring of blood pressure in home or used by the 

licensed healthcare personnel in hospital.

 

 

Precaution

Please read the enclosed instruction. 

 

2. Product Feature 

Scope

Measurement of Human Blood Pressure and Pulse Rate for adults 

Body 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

                                      

Fig 1 

Back of unit                       

 

Battery 

cover                     

Содержание PHBPB16TL

Страница 1: ...ant Noted 6 4 2 Fitting the cuff 6 4 3 Body posture during measurement 7 4 4 Take Measurement 7 4 5 Data Transmission 8 4 6 Memory 9 5 Error Indication 9 6 Trouble Shooting 9 7 Specification 10 8 Abou...

Страница 2: ...o vibration such as ambulances and emergency helicopters A location where there is gas or flame A location where there is water or steam A location where chemicals are stored A location where the unit...

Страница 3: ...h several trials of testing to ensure the measurement accuracy The end user should conduct a manufacturer recommended inspection and calibration annually Blood pressure measurements determined with th...

Страница 4: ...Cuff Type BF Applied Part Model PHBPB16TL Applicable Arm Circumference 8 6 to 14 inches Note Symbol for TYPE BF APPLIED PART Display...

Страница 5: ...r demonstration purpose It is possible these batteries will therefore not last for 200 measurements The battery life can be confirmed in the bottom right of the display If the low battery symbol is di...

Страница 6: ...at can raise blood pressure Try not to take your blood pressure if you are nervous or upset If you are nervous anxious or agitated your blood pressure will rise Rest for 5 10 minutes before taking a r...

Страница 7: ...ensure the measurement accuracy 4 3 Body posture during measurement Relax place the elbow on the desk with palm facing up cuff should be at the heart level Fig 9 The reading accuracy may be affected...

Страница 8: ...ic pressure is greater or equal to 90mmHg as abnormal The display will flash to remind the end user of the blood pressure abnormality If the device caused any discomfort during measurement or fail to...

Страница 9: ...e memory mode and turn off 5 Error Indication List of Error code Error Cause How to correct Er 30 Power on cuff inflation rate is too low or main unit does not connect with the cuff 1 Reconnect the ai...

Страница 10: ...during the day which also will affect by the human emotional and physical condition 2 Record the variance and consult to the doctor If the above suggestion doesn t remediable please dial Pyle Technic...

Страница 11: ...Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC s and mobile cellular telephones medical devices in use may be susceptible...

Страница 12: ...oltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Not applicable...

Страница 13: ...ions equipment and the EQUIPMENT or SYSTEM The EQUIPMENT or SYSTEM is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of th...

Страница 14: ...axed person and still have HBP Let s look at the facts about blood pressure so you can better understand how your body works and why it is smart to start protecting yourself now no matter what your bl...

Страница 15: ...morning blood pressure and this happens in 50 of the cases Patients with morning hypertension have a 78 more chance of stroke compared with 48 of other hypertensive patients without morning high bloo...

Страница 16: ...ymbol for manufacturer 0123 Symbol for CE Symbol for Follow operating instructions Symbol for TYPE BF APPLIED PART Symbol for electrical and electronic equipment IP21 Symbol for the IP classification...

Отзывы: