Parameter name
PiD
Description
TEMPERATURE_
THRESHOLD_LOW *
0x800F
lower temperature value for which
the temperature limitation is being
activated
SMOOTH_DIS_0/P2P_1/
TIM_2 *
0x801A selection of the Smooth function
option
SMOOTH_TIME *
0x801B Smooth time for
tiN
function
chosen in subsection above
NO_SIG_P1-18|SC_19|ON_20|
OFF_21 *
0x801C choice of work mode for No DMX
signal
SCENE_RED *
0x801D settings of red channel value
for scene saved in PX783
SCENE_GREEN *
0x801E settings of green channel value
for scene saved in PX783
SCENE_BLUE *
0x801F settings of blue channel value
for scene saved in PX783
SCENE_WHITE *
0x8020 settings of white channel value
for scene saved in PX783
TEMPERATURE_
THRESHOLD_HIGH *
0x8010
upper temperature value for which
the temperature limitation is active,
i.e. the cut-off temperature for exits
from the driver
BALANCE_RED *
0x8011 value of control level of red channel
balance
BALANCE_GREEN *
0x8012 value of control level of green
channel balance
BALANCE_BLUE *
0x8013 value of control level of blue
channel balance
BALANCE_WHITE *
0x8014 value of control level of white
channel balance