Max ballasts number that are supported by the DALI protocol is limited to 64. To facilitate
programming and to optimize the performance it is recommended to introduce the required
amount of ballast by the user. You can do this as follows:
After running the converter to go to the menu by pressing the ENTER button, then pressing
NEXT or PREV to go to the menu and press ENTER.
Then go to the menu using NEXT or PREV buttons and press ENTER. Then select the
desired number of ballasts and pressing ENTER.
After this operation, the menu will only show number of ballast addresses which was
approved on the menu .
To start programming, at a beginning the DALI devices should be given the addresses. This can
be done in two ways: manually (by users), auto (the converter itself gives the addresses of the
DALI devices.) It is recommended to manually set the addresses.
To automatically assign addresses to ballasts you need in the menu
choose the ,
submenu using buttons NEXT or PREV, press ENTER. Then select and confirm by
pressing ENTER. When on the
display will appear press ENTER. The converter
will start automatically search the network in order to give addresses to encountered ballasts.
The display will start to flash, and found ballasts will in turn on. Addresses will be assigned in the
same order as they were detected starting from 001.
To manually assign addresses you need to go to the menu using buttons NEXT or PREV,
and confirming with ENTER. Then select and confirm with ENTER. When on the converter
display will appear , press ENTER. To begin the process of locating ballast proceed as
follows:
While the converter looks for ballasts on the display blinks with message , after detecting
lamp it lights up and on the screen flashes the suggested address of the ballast. You can change
the address using buttons NEXT or PREV. To accept press the ENTER button, after that the
ballast dims. This process is repeated until the final weights will be found.
The procedure can interrupted by ESC button.
Note.
Number of visible and available addresses for the lamp depends on the number of units
declared by the user when selecting a quantity of ballast in the menu.
If necessary, increase this value (see chapter 4.5).