PC200 PVA
Revision G (2019)
32 of 56
Figure 56: O-rings in the Fluid Manifold
40.
With the lettering on the front, put the fluid manifold on the seal plate and
install four machine screws.
Figure 57: Fluid Manifold Aligned with Valve
41.
Use a 5/32” hex key to tighten the screws.
42.
The PC200 valve and its mechanical portion are now assembled.
43.
Additional air and fluid fittings should be correctly sized and installed in the
applicable ports on the valve for operation.
Figure 58: Assembled Valve