PC200 PVA
Revision G (2019)
23 of 56
Assemble the Valve
This section shows how to assemble PC200 series valves (Standard PC200R process
is shown).
Some installation steps that involve rods, lip seals, sleeve bearings, and O-rings will
differ between the R and RW series of the PC200. Not all options are shown. Valve
series are closely related. When procedures are different from what is shown, “Notes”
are given. If you have questions about procedure steps, parts, or content, contact PVA’s
customer service department.
Procedure
1.
Apply removable thread lock to a machine screw.
2.
Put the screw with thread lock in the piston.
3.
Put a rod in into the countersunk side of the piston.
Figure 30: Install Screw in the Piston-Rod Assembly
4.
Use a 3/16” wrench (or an adjustable wrench) on the flats of each rod to hold
them in place and tighten the screw with a 7/64” hex key. The screw will
engage the rod.
5.
Repeat steps 1-4 for the second rod and machine screw.
Figure 31: Rods and Piston
NOTE: RW-series PC200 uses two different size rods.