PV Powered LLC
18
11-18-28-704
3.2 LED Indicator Lights/Vacuum Fluorescent Display
3.2.a LED Indicator Lights (Model PVP1100)
The StarInverter PVP1100 displays 7 LED indicator lights visible through the upper left
corner of the front panel. Refer to Figure 20.
These lights will indicate the PVP1100’s status and real-time output power into the AC
Grid.
If the PVP1100’s operating environment is safe to produce power into the AC grid, the
“OK” (Green) LED is illuminated.
If at any moment the operating environment moves outside the safe operating limits,
governed by UL 1741, IEEE 519, and NEC 690, the “FAULT” (Red) LED indicator will be
illuminated.
The StarInverter is continuously monitoring:
1. The AC grid connection to ensure the AC voltage and frequency levels are within
safe operating limits (per UL and NEC specifications).
2. The DC PV panel input(s) to ensure safe operating conditions (per UL and NEC
specifications).
3. The PVP1100 itself to ensure only safe operating conditions exist within the
PVP1100’s operating environment.
If all 3 conditions are met the inverter will illuminate the “OK” (Green) LED.
If any one of the operating conditions is not met there is a fault and the PVP1100 will
illuminate the “FAULT” (Red) LED.
The “FAULT” (Red) LED will illuminate when the PV panel voltage is not within safe
operating limits. This will occur at sunset, when the inverter will turn off for the night. It
may also occur when clouds reduce the amount of sunlight, or when the panels are
covered with snow. Anytime the level of sunlight is too low to produce 90 volts of DC
input (the low end of the PVP1100’s operating range) the inverter will turn off. This
ensures only safe and clean (low distortion) power is being generated. When the panels
are once again exposed to enough sunlight, the PVP1100’s auto-start feature will begin,
and after 5 minutes, the “OK “ (Green) LED should illuminate.
If the “FAULT” (Red) LED continues to illuminate when there is sufficient sunlight for
operation, verify all wiring connections are solid. See Section 4.0 Troubleshooting. If the
PVP1100 Command Center is communicating with the inverter, the exact operating
conditions can be determined in real-time.