PV Powered LLC
16
11-18-28-704
2.3.e Connecting Communications (Optional Step)
To connect the communications and load the software follow the steps outlined below
(Refer to Figures 18 and 19):
1. Hardwire the communications cable to the communication terminal, or plug in the
D-sub cable to the serial port.
Figure 18: Communications located on the Power Distribution Board
Serial Connection Table
Figure 19: Hardwiring the serial connection
2. Replace the front cover of the StarInverter and tighten the two or four screws
located on the cover.
5 Pin Screw
Terminal
Connector
Serial Cable
Serial Function
1
7
Request to Send (RTS)
2
2
Receive Data (Rx)
3
4
Data Terminal Ready (DTR)
4
3
Transmit Data (Tx)
5
5
Signal Ground (SG)