8
3. DC APPLICATION (option)
This usage is applicable to 12V battery charging only.
(a)
Charging instruction for battery
Disconnect the leads for the battery.
Make the battery fluid filler cap loose fully.
Fill distilled water to the upper limit, if the battery fluid is low level.
Measure the specific gravity for the battery fluid by using the hydrometer,
and calculate the charging time in according with the table shown on right
side.
The specific gravity for the fully charged battery shall be within 1.26 to
1.28. It is recommended to confirm every hour.
(b)
Connect between the DC output socket and the battery terminals using
the charging leads. The leads shall be connected making sure of the (+)
and (-) polarity.
(c)
The DC circuit protector is to be set to ON after confirming the connection,
if the protector is in OFF position.
CAUTION:
──────────────────────
Be sure the economy control switch is turned OFF while charging the
battery.
───────────────────────────
3
)
STOPPING THE ENGINE
1.
Turn off the power switch of the electric apparatus or disconnect any
electric devices.
2.
Turn the engine switch to STOP position.
3.
Turn the fuel cock lever to OFF.
4.
Turn the fuel tank cap air vent knob counterclockwise to the CLOSED
position.
.
3
2
1
C
Speci
fic grav
ity 20
¡ã
3. 47AH 20HR
2. 35AH 20HR
1. 30AH 20HR
Battery capacity
chargong time Hr
8
10
4
6
2
0
1.06
1.14
1.10
1.22
1.18
1.26
1.30
Aim for specific gravity and charging time
ON
STOP
ENGINE
SWITCH
OFF
C
LO
SE
O
P
E
N
CLOSE