PUREWAVE DG-1500W Скачать руководство пользователя страница 15

14

 

 

8.

 

SPECIFICATION 

 

MODEL 

950i 

1500i 

G

EN

ER

AT

O

Type 

Inverter Generator 

AC Voltage 

50Hz 

100V, 220V, 230V, 240V 

60Hz 

100V,110V, 120V,220V, 240V 

Max. Output 

0.80 kW 

1.5kW 

Rated Output 

0.70 kW 

1.2 kW 

Power Factor 

1.0 

DC Output 

12V / 4.0A (Option) 

EN

G

IN

Model 

PureWave DG-950 

PureWave DG-1500 

Type 

Air-cooled, 4 cycle, OHV, Gasoline Engine 

Bore

×

Stroke        mm

×

mm 

39

×

33.5 

44

×

39.5 

Displacement 

40 cc 

60 cc 

Max. Output 

0.9KW / 5500rpm 

1.5KW / 5500rpm 

Fuel 

Regular Automobile Gasoline 

Fuel tank Capacity 

2.1 liters 

3.0 liters 

Rated Continuous Operation 

4.1 hr 

4.8 hr 

Lubricating oil 

SAE 10W30 

Lubricating oil Capacity 

0.25 liter 

0.27 liter 

Starting System 

Recoil Starter 

Ignition system 

C.D.I. 

Spark Plug: Type 

CMR6A (TORCH) 

A5RTC (TORCH) 

DI

M

EN

SI

O

Net dimension          L

×

W

×

395

×

209

×

355 mm 

448

×

236

×

392 mm 

Overall dimension    L

×

W

×

425

×

230

×

380 mm 

480

×

255

×

425 mm 

Net Weight 

                20 lb 

30 lb 

Gross Weight 

22 lb 

32 lb 

 

Specifications subject to change without prior notice. 

 

 

Содержание DG-1500W

Страница 1: ...IMPORTANT Please make certain that persons who are to use this equipment thoroughly read and understand this user s manual prior to operation ...

Страница 2: ... O N T R O L F U N C T I O N 3 3 P R E O P E R A T I O N C H E C K 5 4 O P E R A T I O N 6 5 P E R I O D I C M A I N T E N A N C E 9 6 T R O U B L E S H O O T I N G 1 2 7 S T O R A G E 1 3 8 S P E C I F I C A T I O N S 1 4 9 W I R I N G D I A G R A M 1 6 ...

Страница 3: ...ourclothes When operating or transporting the machine be sure it is kept upright If it tilts fuel may leak from the carburetor or fueltank 3 ENGINEANDMUFFLERMAYBEHOT Placethemachineinaplacewherepedestriansorchildrenarenotlikelytotouchthemachine Avoidplacinganyflammablematerialsneartheexhaustoutletduringoperation Keepthemachineatleast1m 3ft frombuildingsorotherequipment ortheenginemayoverheat Avoid...

Страница 4: ...neswitch 3 Fueltank 4 Sparkplug 5 Muffler 6 Carryinghandle 7 Chokelever 8 ACpilotlight 9 Overloadindicatorlight 10 Oilwarninglight 11 Ground earth terminal 12 DCprotector 13 DCreceptacle 14 ACreceptacle 15 FrequencyTransferSwitch 16 Fuelfilter 17 Fueltankcap 18 Fuelpump 19 Recoilstarter 20 Fuelcock 21 Oilfillercap 22 Airfiltercover 1 2 3 4 5 6 8 9 10 11 12 13 14 16 17 19 20 7 15 18 21 22 ...

Страница 5: ...terfuelconnectionandlessnoise 4 DCCIRCUITPROTECTOR The DC circuit protector turns off automatically when the load exceeds the generatorratedoutput CAUTION Reducetheloadtowithinspecifiedgeneratorratedoutputifthe DCcircuit protectorturnoff 5 FUELTANKCAPAIRVENTKNOB The fuel tank cap is provided with an air vent knob to stop fuel flow The air vent knob must be turned once clockwise from the closed pos...

Страница 6: ...of the fuel filter or it may overflow when the fuel heatsuplaterandexpands Wipeoffspiltfuelthoroughlybeforestartingengine Keepopenflamesaway 2 CHECKENGINEOIL Make sure the engine oil is at the upper level of the oil filler hole Add oil as necessary Removeoilfillercapandchecktheengineoillevel If oil level is below the lower level line refill with suitable oil to upper level line Donotscrewintheoilf...

Страница 7: ...n Notnecessaryif theengineiswarm 6 Pull the starter handle slowly until resistance is felt This is the Compression point Return the handle to its original position and pull swiftly Do notfully pull outtherope Afterstarting allowthestarter handle to return to its original position while still holding the handle Grasp the carrying handle firmly to prevent the generator from falling over when pulling...

Страница 8: ...g power to the generationinordertoprotectthegeneratorandanyconnectedelectricdevices The output pilot light green will flicker and the overload indicator light red will turnon thentheenginewillstoprunning Ifsopleasefollowthefollowingsteps a Turnoffanyconnectedelectricdevicesandstoptheengine b Reduce the total wattage of connected electric devices within the applicationrange c Check for blockages in...

Страница 9: ...ls using the charging leads The leads shall be connected making sure of the and polarity c TheDCcircuitprotectoristobesettoONafterconfirmingtheconnection iftheprotectorisinOFFposition CAUTION Be sure the economy control switch is turned OFF while charging the battery 3 STOPPINGTHEENGINE 1 Turn off the power switch of the electric apparatus or disconnect any electricdevices 2 TurntheengineswitchtoS...

Страница 10: ...uel cock filter Replace if necessary Choke Checkchokeoperation Valve Clearance Check and adjust when engine iscold FuelLine Check fuel hose for crack or damage Replaceifnecessary Exhaust System Check for leakage Retighten or replacegasketifnecessary Checkmufflerscreen Clean replaceifnecessary Carburetor Checkchokeoperation Cooling system Checkfandamage Starting system Checkrecoilstarteroperation I...

Страница 11: ...mendedengineoil seepage14 15 APIService SJ CAUTION Besurenoforeignmaterialentersthecrankcase Do not tilt the generator when adding engine oil This could result in overfillinganddamagetotheengine Cleantheoilfiltereveryother100hr 3 AIRFILTER Maintaining an air cleaner in proper condition is very important Dirt induced through improperly installed improperly serviced or inadequate elements damagesand...

Страница 12: ... Cleanthefilterwithsolvent Ifdamaged replace 3 Wipethefilterandinsertit WARNING Besurethetankcapistightenedsecurely 6 MUFFLERSCREEN WARNING Theengineandmufflerwillbeveryhotaftertheenginehasbeenrun Avoidtouchingtheengineandmufflerwhile they arestill hotwithany part ofyourbodyorclothingduringinspectionorrepair 1 Removethecover 2 Removethemufflerscreen 3 Usetheflatheadscrewdrivertoprythesparkarrester...

Страница 13: ...ntknobtoOPEN fuelcockknobtoON Cloggedfuelline Cleanfuelline Cloggedcarburetor Cleancarburetor 2 Engineoilsystem Insufficient Oillevelislow Addengineoil 3 Electricalsystems Poorspark Sparkplugdirtywithcarbonorwet Removecarbonorwipesparkplugdry Faultyignitionsystem Consultdealer 4 Compressioninsufficient Wornoutpistonandcylinder Consultdealer 2 Generatorwon tproducepower Safetydevice AC to OFF Stopt...

Страница 14: ...2 ENGINE 1 Remove the spark plug pour in about one tablespoon of SAE 10W30 or 15W40 motor oil into the spark plug hole andreinstallthesparkplug 2 Usetherecoilstartertoturntheengineoverseveraltimes withignitionoff 3 pulltherecoilstarteruntilyoufeelcompression 4 Stoppulling 5 Cleanexteriorofthegeneratorandapplyarustinhibitor 6 Storethegeneratorinadry well ventilatedplace withthecoverplaceoverit 7 Th...

Страница 15: ...33 5 44 39 5 Displacement 40cc 60cc Max Output 0 9KW 5500rpm 1 5KW 5500rpm Fuel RegularAutomobileGasoline FueltankCapacity 2 1liters 3 0liters RatedContinuousOperation 4 1hr 4 8hr Lubricatingoil SAE10W30 LubricatingoilCapacity 0 25liter 0 27liter StartingSystem RecoilStarter Ignitionsystem C D I SparkPlug Type CMR6A TORCH A5RTC TORCH DIMENSION Netdimension L W H 395 209 355mm 448 236 392mm Overall...

Страница 16: ... SPARK PLUG SPRING WINDING CONTROL PANEL BLOCK GENERATOR BLOCK ENGINE BLOCK GROUND TERMINAL GRAY YELLOW GREEN PI Gr PINK Y G ORANGE YELLOW O Y BL Bu BLACK BLUE BROWN RED Br R W WHITE G GREEN P ENGINE SWITCH W BL W P BL O R Y G Y G Y G Bu Bu Bu BL R BL P PURPLE DC OUTPUT ECO SWITCH IGNITION CONTROLLER STEPPER MOTOR ASSY RECTIFIER IGNITION COIL R DC PROTECTOR 4 5A FUSE 15A R BL R BL Y G AC OUTPUT R ...

Отзывы: