UF Series User Guide

GENERAL OPERATION 

Plug into an uninterrupted electrical outlet. 
Note: the system transformers are not weather resistant and should 
be adequately protected. All electrical connections must be connected 
accordingly to local codes. 

When the system is operating one of two displays will be shown. Pressing 

▲ 

or 

 button will alternate between the displays. One of the displays is 

always the current time of day (to the nearest hour). 

The second display is the days remaining until the next regeneration. If the 

days remaining is equal to one, a generation will occur at the next present 

regeneration time. The user can scroll between displays as desired.

If the system has called for a regeneration that will occur at the present 

time of regeneration, the arrow will point to Regen.

OTHER SETTINGS - 

these have been factory set (only adjust if required)

1

3

Time - Hour
PM
Days To Regen

Regen
Min. Fill
Regen
Hour

SET

SET

1

2

SET

SET

Time - Hour
PM
Days To Regen

Regen
Min. Fill
Regen
Hour

OR

Time - Hour
PM
Days To Regen

Regen
Min. Fill
Regen
Hour

SET

SET

Time - Hour
PM
Days To Regen

Regen
Min. Fill
Regen
Hour

RETURN TO 

NORMAL MODE

Time - Hour
PM
Days To Regen

Regen
Min. Fill
Regen
Hour

SET

2

Step 1

: From normal mode, press SET + 

 buttons simultaneously for 5 

seconds and release.

Step 2:

 Regeneration Time: Set the clock to the hour the regeneration 

should occur by using the 

 or 

 buttons.  Once the hour is chosen, 

press SET and repeat for MINUTES. Factory setting is 2 AM.   

Press SET to go to STEP 3.

Step 3:

 Days to regeneration: This is factory set to 1 (1 days between 

regeneration). The allowable range is 1 to 99. Refer to "Regeneration" to 

set correct regeneration days.  

Press SET to exit Installer Displays and Settings.

The system is factory set to regeneration at 2 AM. If there is a demand for 

water when the system is regenerating, untreated water will be used.

SET TIME OF DAY

Step 1

: Press SET for 5 seconds

Step 2:

 Current time: set HOUR by using the 

 + 

 button then press 

SET. Repeat for MINUTES. 

After a power outage, the time of day will need to be reset. 

Programming

Time - Hour
PM
Days To Regen

Regen
Min. Fill
Regen
Hour

SET

SET

Time - Hour
PM
Days To Regen

Regen
Min. Fill
Regen
Hour

An arrow points to the 

word Regen if a regenera-

tion is expected ‘Tonight’.

POWER LOSS

If the power goes out current time of day will need to be reset.  If the 

power goes out while the system is regenerating, the cycle picks up where 

it was interrupted when the power returns.  

Note: The display will flash if a power outage has occurred.

MANUAL REGENERATION

 

Sometimes there is a need to regeneration the system sooner than when 

the system calls for it, usually referred to as a manual regeneration. There 

may be a period of heavy water usage because of guests or a heavy 

laundry day.

To initiate a manual regeneration at the preset delayed regeneration time, 

simultaneously press 

 + 

 buttons together and release. The arrow will 

point to the word Regen if a regeneration is expected ‘tonight’. To cancel 

the regeneration simultaneously press 

 + 

 buttons and release.

To initiate a manual regeneration immediately, simultaneously press 

 

 buttons together for 3 seconds. The system will begin to regenerate 

immediately. The request cannot be cancelled. 

REGENERATION MODE

When the system begins to regeneration, the display will change to 

indicate the cycle of the regeneration process that is occurring and an 

arrow will also point to regen. The system will run through the steps 

automatically and will reset itself to provide treated water when the 

regeneration is completed.

Содержание UF10 Series

Страница 1: ...r Guide Membrane Filtration System UF10 Series SET For correct operation installation it is essential to observe these instructions OCT2020 DO DO LIQ SU RE NO SURGE PROTECTION REQUIRED NO EXTENSION CO...

Страница 2: ...020 Puretec Customer Service 3 Installation Record 4 Water Analysis Details 4 Before Installation 5 Exploded Diagram 6 Replacement Parts 7 Installation 8 9 Start Up 10 12 Bypass Valve 11 Programming 1...

Страница 3: ...ystem after and period of non use more than 1 month Note For point of entry installations an approved dual check backflow prevention device must be installed When line pressure exceeds 690kPa a pressu...

Страница 4: ...lumber Details Water Analysis Information Hardness ___________ ppm mg L Iron ___________ ppm mg L Manganese ___________ ppm mg L pH ___________ TDS Total Dissolved Salts ___________ ppm mg L Conductiv...

Страница 5: ...this will protect the system fouling prematurely Install in correct relationship to other water treatment equipment Contact Puretec for assistance Water temperatures outside 0 37 C will damage the sy...

Страница 6: ...6 Installation Operation Manual Copyright Puretec Pty Ltd 2020 4 1 6 11 13 9 10 8 7 2 3 12 5 TankSafe Ta nk Sa fe TankSafe TankSafe TankSafe TankSafe TankSafe TankSafe Exploded Diagram...

Страница 7: ...Valve WTV4000 4 Transformer Suits Auto Valves WTV5135 5 Drain Tube Assembly 6 1 Plastic Fitting Kit WTV5060 7 Bypass Assembly if purchased WTV5000 8 Ball Valve KSOV66 9 Reducing Elbow KRS64 10 Check...

Страница 8: ...e in accordance with local plumbing codes The pipe size for the drain line should be a minimum of 5 8 Avoid getting primer and solvent cement on filter system Install grounding strap on metal pipes if...

Страница 9: ...on of the drain port Insert the drain tube assembly and reinsert the red clip Connect extra tube tubing not supplied onto the 5 8 drain line from the valve to the drain The length of drain line should...

Страница 10: ...lfway into the diagnostic mode Page 9 this will allow water to enter the UF vessel and purge the air to the drain 4 Once the UF vessel is full water will start flowing out the drain Now open the inlet...

Страница 11: ...S SUPPLY WATER ENTERS NO WATER EXITS SUPPLY WATER IS SHUT OFF FROM THE HOUSE THE VALVE TREATED WATER EXITS SUPPLY WATER ENTERS SUPPLY WATER EXITS SUPPLY WATER ENTERS Normal Operation Bypass Operation...

Страница 12: ...er the UF vessel and purge the air to the drain 4 Once the UF vessel is full water will start flowing out the drain Now open the inlet valve completely and allow water to drain for 20 minutes This wil...

Страница 13: ...eration days Press SET to exit Installer Displays and Settings The system is factory set to regeneration at 2 AM If there is a demand for water when the system is regenerating untreated water will be...

Страница 14: ...he flush valve Monthly TankSafe Backwash Clean Manual Operation The UF system requires a chemical backwash every month to cleanse the system from microbiological and organic build up 1 Ensure that the...

Страница 15: ...tly C Reset regeneration time Time of day flashes on and off A Power outage s A Reset time of day replace battery CR2032 and then perform a dry reset Valve does not regenerate when performing a manual...

Страница 16: ...ater pressure A Check incoming water pressure water pressure must remain at minimum of 25 psi B Incorrect injector size B Replace injector with correct size for application C Restricted kinked drain l...

Страница 17: ...le to read middle reduction gear C Check foil on reduction gear clean any foreign material on the foil D Missing damaged reduction gears D Replace missing gears E Defective PC Board E Replace PC Board...

Страница 18: ...ed False and incorrect claims will be pursued at Puretec s discretion including chargeable inspection and labour costs incurred Warranty Australia This warranty is given by Puretec Pty Ltd ABN 44 164...

Страница 19: ...19 Copyright Puretec Pty Ltd 2020 UF Series User Guide...

Страница 20: ......

Отзывы: