8
Installation & Operation Manual
Copyright © Puretec Pty Ltd 2020
WARNINGS
•
The control valve, fittings and/or bypass are designed to accommodate minor
plumbing misalignment but are not designed to support the weight of a
system or the plumbing.
•
Do not use petroleum jelly, oils, other hydrocarbon lubricants or spray silicone
anywhere. A silicon lubricant may be used on the black O-rings but it is not
necessary.
•
Do not use pipe dope or other sealants on threads. Thread seal tape is the
preferred sealant but is not necessary on the nut connection or caps because
of O-ring seals.
•
All plumbing should be done in accordance with local plumbing codes. The
pipe size for the drain line should be a minimum of 5/8”.
•
Avoid getting primer and solvent cement on filter system.
•
Install grounding strap on metal pipes if required.
•
Ensure the system is protected against high pressure and extreme
temperatures.
Installation
1. Unpack the equipment. Locate and identify the parts as shown on page 6:
2. Extra items required (not supplied):
• Bypass Assembly
• 2L bottle of TankSafe
• 5/8” tubing for drain
3. Ensure water has been tested, input values into Table on Page 4 and the analysis has been
inspected by Puretec.
4. Position the system on a level surface.
Environmental Conditions
Operating temperature: 0-45
°
C
Water Conditions
Temperature: 0-37
°
C
Pressure: 350-690kPa
Electrical supply – 240V, 50Hz uninterrupted outlet (weather protected)