12 

Installation & Operation Manual

Copyright © Puretec Pty Ltd 2020

Start-Up – NO Bypass Installed 

Now programming is completed (if required) you are ready to start the system. 

(If bypass is installed, refer to Page 10)

 

1. Ensure the inlet valve, flush valve and TankSafe suction line valve are closed (see Page 6 for 
identification). Turn the water supply on, do not open the inlet valve. Note: The inlet valve will 
be opened in Step 3. 

2. Press and hold the UP and DOWN arrows simultaneously and release when the valve goes 
into backwash, 'C1’ will be flashing on the display to indicate when the unit is in backwash. 

3. Press the DOWN arrow to advance the valve to the TankSafe draw cycle (valve will display 
‘C2’). Press the DOWN arrow a second time to advance the valve to the rinse cycle (valve 
will display ‘C4’). Slowly open the inlet valve to half flow, this will allow water to enter the UF 
vessel and purge the air to the drain. 

4. Once the UF vessel is full, water will start flowing out the drain. Now open the inlet valve 
completely, and allow water to drain for 20 minutes. This will allow for a complete flush of the 
system, and any preservatives used in the manufacturing process. 

5. The valve will return to the normal service position after 20 minutes. 

6. Repeat steps 2-5 with the inlet valve open this will dispel any excess air from the system. 
Proceed to the next step when all the air has been purged by pressing the DOWN arrow a third 
time to advance the valve to the refill cycle (valve will display ‘C5’) and then press the DOWN 
arrow a final time to end the backwash (valve will display ‘C0’) Note: it is not necessary to 
flush the system for 15 minutes as per step 3.

7. Once the valve is in the normal service position, open the outlet valve. 

8. Open the nearest tap downstream of the filter system (after the filter system). Flush the 
system until the water is clear. 

9. Close the opened tap and check for leaks. 

10. Your system is ready for use.

Содержание UF10 Series

Страница 1: ...r Guide Membrane Filtration System UF10 Series SET For correct operation installation it is essential to observe these instructions OCT2020 DO DO LIQ SU RE NO SURGE PROTECTION REQUIRED NO EXTENSION CO...

Страница 2: ...020 Puretec Customer Service 3 Installation Record 4 Water Analysis Details 4 Before Installation 5 Exploded Diagram 6 Replacement Parts 7 Installation 8 9 Start Up 10 12 Bypass Valve 11 Programming 1...

Страница 3: ...ystem after and period of non use more than 1 month Note For point of entry installations an approved dual check backflow prevention device must be installed When line pressure exceeds 690kPa a pressu...

Страница 4: ...lumber Details Water Analysis Information Hardness ___________ ppm mg L Iron ___________ ppm mg L Manganese ___________ ppm mg L pH ___________ TDS Total Dissolved Salts ___________ ppm mg L Conductiv...

Страница 5: ...this will protect the system fouling prematurely Install in correct relationship to other water treatment equipment Contact Puretec for assistance Water temperatures outside 0 37 C will damage the sy...

Страница 6: ...6 Installation Operation Manual Copyright Puretec Pty Ltd 2020 4 1 6 11 13 9 10 8 7 2 3 12 5 TankSafe Ta nk Sa fe TankSafe TankSafe TankSafe TankSafe TankSafe TankSafe Exploded Diagram...

Страница 7: ...Valve WTV4000 4 Transformer Suits Auto Valves WTV5135 5 Drain Tube Assembly 6 1 Plastic Fitting Kit WTV5060 7 Bypass Assembly if purchased WTV5000 8 Ball Valve KSOV66 9 Reducing Elbow KRS64 10 Check...

Страница 8: ...e in accordance with local plumbing codes The pipe size for the drain line should be a minimum of 5 8 Avoid getting primer and solvent cement on filter system Install grounding strap on metal pipes if...

Страница 9: ...on of the drain port Insert the drain tube assembly and reinsert the red clip Connect extra tube tubing not supplied onto the 5 8 drain line from the valve to the drain The length of drain line should...

Страница 10: ...lfway into the diagnostic mode Page 9 this will allow water to enter the UF vessel and purge the air to the drain 4 Once the UF vessel is full water will start flowing out the drain Now open the inlet...

Страница 11: ...S SUPPLY WATER ENTERS NO WATER EXITS SUPPLY WATER IS SHUT OFF FROM THE HOUSE THE VALVE TREATED WATER EXITS SUPPLY WATER ENTERS SUPPLY WATER EXITS SUPPLY WATER ENTERS Normal Operation Bypass Operation...

Страница 12: ...er the UF vessel and purge the air to the drain 4 Once the UF vessel is full water will start flowing out the drain Now open the inlet valve completely and allow water to drain for 20 minutes This wil...

Страница 13: ...eration days Press SET to exit Installer Displays and Settings The system is factory set to regeneration at 2 AM If there is a demand for water when the system is regenerating untreated water will be...

Страница 14: ...he flush valve Monthly TankSafe Backwash Clean Manual Operation The UF system requires a chemical backwash every month to cleanse the system from microbiological and organic build up 1 Ensure that the...

Страница 15: ...tly C Reset regeneration time Time of day flashes on and off A Power outage s A Reset time of day replace battery CR2032 and then perform a dry reset Valve does not regenerate when performing a manual...

Страница 16: ...ater pressure A Check incoming water pressure water pressure must remain at minimum of 25 psi B Incorrect injector size B Replace injector with correct size for application C Restricted kinked drain l...

Страница 17: ...le to read middle reduction gear C Check foil on reduction gear clean any foreign material on the foil D Missing damaged reduction gears D Replace missing gears E Defective PC Board E Replace PC Board...

Страница 18: ...ed False and incorrect claims will be pursued at Puretec s discretion including chargeable inspection and labour costs incurred Warranty Australia This warranty is given by Puretec Pty Ltd ABN 44 164...

Страница 19: ...19 Copyright Puretec Pty Ltd 2020 UF Series User Guide...

Страница 20: ......

Отзывы: