5
HYBRIDPLUS SERIES
| Complete Household Water Filtration & Pressure System
Positioning Your System
Positioning Your System
Choose a location with a structurally appropriate position. Allow a chamber length space
above the unit for removal of the lamp and sleeve from the Radfire UV system during
servicing and allowance for the swing doors to open (see Fig. 5).
To protect your HybridPlus system make sure the site is frost free and has adequate
ventilation. Choose a location with adequate drainage and where water spillage will not
cause damage that may occur over time from leaking pipe joints or seals.
Power Surge Protection
An electrical power surge or spike can travel on the supply lines and cause serious
damage to your electrical equipment. The Radfire UV Electronic ballast has a fuse
(non-replaceable) to protect the circuit. The fuse is not a lightning arrester and may not
protect the Radfire if lightning or a very powerful surge hits the unit.
A suitable surge protection device has been provided with this product. Puretec
recommends the use of a surge protector (the one supplied or otherwise) or warranty
may be voided.
WARNING: The Arlec power surge protector that is provided is not
weatherproof & MUST be protected from water/moisture.
It would usually be sufficient for the surge protector to be installed under the eaves of
a house and/or out of the weather, otherwise, it would need to be suitably protected.
Ensuring the surge protector is suitably protected from water/moisture is the
responsibility of the user. Alternatively a hard-wired outdoor surge protector my be
installed by a qualified electrician or an outdoor rated surge protector may also be used.
Re-order code for surge protectors: PC-SURGE
Do not use long extension leads as they may cause substantial voltage drop and/or poor
lamp performance.
We recommend the use of an RCD or earth leakage circuit breaker
on the power