Operation
Cartridge Installation / Replacement
To change the filter cartridges adhere to the following procedure.
1. Turn mains water supply off.
2. Relieve water pressure by operating faucet lever.
3. Unscrew Filter Housing using the spanner wrench and discard cartridges. When
removing housings place a container underneath to catch any spillage.
4. Cleanse the inside of the housing using hot water and detergent. Check O-Ring
and lubricate with food grade silicone lubricant (or similar). Replace O-Ring if
kinked or damaged.
UV Lamp Installation / Replacement
• Prior to performing any work on the UV steriliser system, always disconnect the
power supply and allow unit to cool.
Warning: Do not look directly into ultraviolet rays emitted from the UV lamp as
they will cause serious burns to unprotected eyes.
• The treated water will seem warm for a short period at first flow. This is because the
UV lamp emits heat to kill bacteria. When turning on a tap, let the water run for a
short time to purge any warm water.
Aluminium
Nut
Water Outlet
O-Ring
Lamp Power
Connector
Quartz
Sleeve
UV Lamp
Aluminium
Nut
Cap
Ballast
Stainless Steel
Chamber
O-Ring
Water Inlet
Fig. 2