HYD-2100.
CNC Plasma&Flame Cutting Control System
Edition of 28.07.2015
46
www.purelogic.ru
8 (800) 555 63 74
1
Right limit
14
2
15
3
16
4
17
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13
Left limit
Front limit
Back limit
Emergency Stop
Arcing
successfully
Positioning
successfully
Plasma collision
ignition
Cutting oxygen
Torch up
Torch down
Move left
NC
Move right
NC
Move ahead
NC
Move backward
NC
NC
+24V
+24V
24VG
24VG
com
Right limit input
Left limit input
Front limit input
Back limit input
Emergency
stop input
Arcing
successfully
feedback
Positioning
successfull
y feedback
Plasma
collision
feedback
1.For Plasma cutting
2.Accessed when CNC positioning is
needed. And positioning successfully
input should be configured as
normally open type. Or it can be not
accessed when using height adjusting
device to positioning.
3.When plasma collision detection is
needed, accessed to plasma collision
feedback.
Caution: All inputs can be
normally closed or normally
open, and all inputs are
normally open in defualt.
(
connecting to 24VG of the
system or connecting to the 24VG
of the external 24V switching
power supply.
)
Remote Input
The system supports two external remote control input, one for line input type,
the other for 8421 encoded input type.
• Line Input Type
The pin 7, 8, 9, 10 of input port represents left, right, forward, backward, when
inputting valid signal , the machine can move toward the corresponding direction,
when the input signal is invalid, the machine stop moving.
When the input signal of pin 16 is valid, the system will ignite the torch, the
ignition time is the setting value in system parameters, please take the reference
of part of «ignition time» in «7.2 oxygen gas parameters».
When the input signal of pin 17 is valid, the system will turn on or off the
cutting oxygen. When the cutting oxygen is on, the system cut off the oxygen,
when the cutting oxygen is off, open the cutting oxygen system.
When the input signal of pin 18 is valid, the system will raise the cutting torch,
when the signal invalid, the torch stops.
When the input signal of pin 19 is valid, the torch goes down, when the signal
invalid, the cutting torch stops.
The external switches of line input are designed by the user.
• 8421 code input
Input pin 9, 10, 7, 8 is the A, B, C, D bits of the 8421 code.