Enter the Disconnect command below. Replace the “#”s with the Input and Output
number(s).
*255DI#O#!
Note) For PM-128X and PM-256X, input and output # uses three digit format, instead
of two digits. For example;
Input 01 (I001), Input 05 (I005), Output 01 (O001) and Output 100 (O100)
Examples (Disconnect Video and Audio):
Command Codes
Action
*255DI01O00!
Disconnect both Video and Audio Input 1 to no Output (00)
*255DI00O03,04,05!
Disconnects both Video and Audio Outputs 3, 4, and 5
*255DI00O03-06!
Disconnects both Video and Audio Output 3, 4, 5, and 6
*255DALLIO!
Disconnects both Video and Audio all Inputs and Outputs
Examples (Disconnect Video only):
Command Codes
Action
*255VDI01O00!
Disconnect Video Input 1 to no Output (00)
*255VDI00O03,04,05!
Disconnects Video Outputs 3, 4, and 5
*255VDI00O03-06!
Disconnects Video Output 3, 4, 5, and 6
*255VDALLIO!
Disconnects Video all Inputs and Outputs
Examples (Disconnect Audio only):
Command Codes
Action
*255ADI01O00!
Disconnect Audio Input 1 to no Output (00)
*255ADI00O03,04,05!
Disconnects Audio Outputs 3, 4, and 5
*255ADI00O03-06!
Disconnects Audio Output 3, 4, 5, and 6
*255ADALLIO!
Disconnects Audio all Inputs and Outputs
Connection Status Check
A connection status can be checked to confirm that the switch has been correctly executed
or to confirm correct routing to multiple Outputs. The characters and numbers in a status
command tell the system which Input or Output to check.
To check connection status:
Содержание PM-16X
Страница 93: ...PureLink by Dtrovision 93 4 Hyper terminal setting Go to file Properties setting ASCII setup ...
Страница 94: ...PureLink by Dtrovision 94 Check on Echo typed characters locally and then ok 5 Type program and enter ...
Страница 95: ...PureLink by Dtrovision 95 6 Type 1 and enter 7 Go to send T menu and then send file Select Ymodem Protocol ...
Страница 96: ...PureLink by Dtrovision 96 8 Select firmware file rom and then Send S 9 Firmware update progress window ...