PureLink by Dtrovision
61
displays are connected and it will determine which resolution to Output according to the
EDID information received from the display.
The EDID normally includes manufacturer name and serial number, sets of capable
resolution including native resolution, supported timing, pixel mapping data (for digital
displays only) and etc.
In a digital connectivity environment; in order to support the maximum resolution of
connected monitor, EDID handshake is a critical because improper EDID handshake
between sources to the display will result in no image on the display.
EDID handshake may sound simple; however, with multiple peripheral devices within the
chain, display's EDID information easily get lost or blocked while it is traveling to the source
device.
PM series Matrix Router provides Auto EDID management system to meet today's
sophisticated digital connectivity integration environment.
Auto EDID management system
EDID library
14 most widely used EDID data is pre-programmed internal EEPROM chipset which user
can take and save onto the any of the Matrix Router's Input EEPROM.
EDID library list
800 x 600 @ 60Hz
1024 x 768 @ 60Hz
1280 x 768 @ 60Hz
1280 x 1024 @ 60Hz
1360 x 768 @ 60Hz
1366 x 768 @ 60Hz
1400 x 1050 @ 60Hz
1600 x 900 @ 60Hz
1600 x 1200 @ 60Hz
1680 x 1050 @ 60Hz
1920 x 1200 @ 60Hz
HD 1080i @ 60Hz
HD 1080p (2CH)
HD 1080p (Multi)
Factory default EDID is set to 1920 x 1080p@60Hz
By optimizing factory default EDID and EDID library feature, in most cases, PM Matrix
Router will work out of the box without any additional configuration.
Emulation
The user can easily save an EDID data from any display devices directly onto the Matrix
Router's Input port or EDID library's empty spot. By saving display device's EDID
information on the Matrix Router Input port, Input port will act as a display to the Video
source.
Содержание PM-16X
Страница 93: ...PureLink by Dtrovision 93 4 Hyper terminal setting Go to file Properties setting ASCII setup ...
Страница 94: ...PureLink by Dtrovision 94 Check on Echo typed characters locally and then ok 5 Type program and enter ...
Страница 95: ...PureLink by Dtrovision 95 6 Type 1 and enter 7 Go to send T menu and then send file Select Ymodem Protocol ...
Страница 96: ...PureLink by Dtrovision 96 8 Select firmware file rom and then Send S 9 Firmware update progress window ...