9. Testing Your Dryer
NOTE:
Many of the procedures described in this section will be easier with both
System 1 and System 2 operating. It is recommended that you change the System
Cycle Mode to
BOTH
for the following procedures
9.1 Safety & Warning Information
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
Many procedures performed during
installation, operation, testing, and maintenance of this air-dryer
require the equipment to be running, creating a situation for
potential electrical shock. It is highly recommended that you
remove all jewelry before performing any procedures.
WARNING!
Internal surfaces may be hot
. Use care when coming into contact
with internal components as there is a potential for some of these
components to become hot when in operation or standby.
CAUTION!
Depressurizing the air-dryer may be necessary before performing
certain procedures.
NEVER
remove pressure sensing tubes from
the control board without depressurizing the air-dryer first, or
damage to the control board will occur.
WARNING!
High Noise
. ALTEC AIR air-dryers are meant to be installed in an
unattended area.
CAUTION!
Observe precautions for handling
Electrostatic Sensitive Devices.