background image

Page 6

Fountain Classic Owner’s Manual

Getting to Know the Fountain Classic

1.

Photo Display

Photo Display

Photo Display

Photo Display

Photo Display—This is a backlit area to display photos or advertising.  Several

optional displays are available from Pure Water, Inc. or from your local dis-

tributor.

2.

Water Dispensing Area

Water Dispensing Area

Water Dispensing Area

Water Dispensing Area

Water Dispensing Area—Three temperature units have dispensers for Hot

Water, Room Temperature Water, and Cold Water and the two temperature

unit has dispensers for Room Temperature Water and Cold Water.  The

Controls for these are listed in items 14 and 15.

3.

Drip Tray

Drip Tray

Drip Tray

Drip Tray

Drip Tray—The hidden drip tray collects water that spills from the Dipsensing

Area.  This must be routinely emptied to prevent overflows and spillage.

4.

Water Inlet

Water Inlet

Water Inlet

Water Inlet

Water Inlet—Raw water from the local supply enters the machine at this

location.  It is important to use the cold water supply.

5.

Water Inlet Solenoid

Water Inlet Solenoid

Water Inlet Solenoid

Water Inlet Solenoid

Water Inlet Solenoid—This valve automatically opens to allow water to flow into

the Boiling Chamber when the water level is low.

6.

Removable Boiling Chamber

Removable Boiling Chamber

Removable Boiling Chamber

Removable Boiling Chamber

Removable Boiling Chamber—This is where the raw water is heated to boiling.

Contaminants from the water stay in this chamber.  It is important that this

chamber is drained and periodically cleaned of residue per instructions.  For

more information see page 11.

7.

Heating Element

Heating Element

Heating Element

Heating Element

Heating Element—This heating element heats the raw water to boiling.  The

standard heating element is 1400 Watts.

8.

Safety Reset

Safety Reset

Safety Reset

Safety Reset

Safety Reset—This mechanical safety feature ensures that if the heating ele-

ment continues when not covered with water, the unit will turn off automati-

cally.

9.

Boiling Chamber Drain Valve

Boiling Chamber Drain Valve

Boiling Chamber Drain Valve

Boiling Chamber Drain Valve

Boiling Chamber Drain Valve—As the steam evaporates from the raw water, the

contaminants in the water in the boiling chamber can become very concen-

trated.  This valve allows you to drain the contaminants off, so that they do not

build up.

10. Steam Tube

Steam Tube

Steam Tube

Steam Tube

Steam Tube—The steam created in the boiling chamber rises through this tube

to the condensing coil at the top of the unit.

11. Condensing Coil and Fan Assembly

Condensing Coil and Fan Assembly

Condensing Coil and Fan Assembly

Condensing Coil and Fan Assembly

Condensing Coil and Fan Assembly—The steam from the steam tube enters the

condensing coil.  The fan turns on, and sends cooling air past the coil.  The

steam is cooled and condenses to distilled water.  The condensing coil  has

two small volatile gas vents to allow the volatile gases to escape.

Photo

Display 

Here

1

2

3

Содержание Fountain Classic

Страница 1: ...Fountain Classic Installation and Owner s Manual Page 16 4120 NW 44th St Lincoln NE 68524 USA Tel 402 467 9300 Toll Free in the USA 800 875 5915 Fax 402 467 9393 www purewaterinc com...

Страница 2: ...Page 2 Fountain Classic Owner s Manual...

Страница 3: ...ith Your Distiller 5 Optional Accessories 5 Getting to Know the Fountain Classic 6 Installation 8 Maintenance 11 Post Filter Changing and Steam Sterilization 11 Cleaning the Boiling Chamber 12 Trouble...

Страница 4: ...dapters DO NOT DO NOT DO NOT DO NOT DO NOT let children play with the distiller Wait at least 30 minutes after the distiller is off before draining or handling the boiling chamber Do not run the dispe...

Страница 5: ...rsion Part 7276 For 240V units power cord must be at least 10 Amp at 240V grounded cord Owners Manual Owners Manual Owners Manual Owners Manual Owners Manual Not shown Part 6338 Warranty Card Warranty...

Страница 6: ...e raw water is heated to boiling Contaminants from the water stay in this chamber It is important that this chamber is drained and periodically cleaned of residue per instructions For more information...

Страница 7: ...ant Important Important Important Important This switch must be in the OFF position until the storage tank is filled the first time Three temperature unit only 16 Main Electrical Control Box Main Elec...

Страница 8: ...d Pure Water Distributor for other water line connection options NOTE NOTE NOTE NOTE NOTE Do not plug the unit into the power source until instructed to do so The installation of the Fountain Classic...

Страница 9: ...ch Light Switch Light Switch Light Switch OFF OFF OFF OFF OFF Cooler Power Cooler Power Cooler Power Cooler Power Cooler Power OFF OFF OFF OFF OFF Dispenser Hot Water Switch Dispenser Hot Water Switch...

Страница 10: ...tillation Distillation After the unit has adequately steam sterilized turn the Fan switch to the ON position The fan will start and begin to cool the steam After a few minutes distilled water will be...

Страница 11: ...ion Steam Sterilization Steam Sterilization 1 Remove the old post filter from the unit 2 Place the piece of high temperature tubing in place of the post filter It will connect the outlet end of the co...

Страница 12: ...very 2000 hours or every three months Step 1 Step 1 Step 1 Step 1 Step 1 Shutdown and Cooling Shutdown and Cooling Shutdown and Cooling Shutdown and Cooling Shutdown and Cooling 1 Turn the distiller s...

Страница 13: ...se blown Power switch OFF Heating element failure Reset tripped Post filter is depleted or carry over problem Faulty heating element or fan Improper air flow No coolant in compressor Cold temperature...

Страница 14: ...Page 14 Fountain Classic Owner s Manual Wiring Schematic...

Страница 15: ...Fountain Classic Owner s Manual Page 15 Exploded Drawing 48998 Two Temperature Unit...

Страница 16: ...1 7138 7138 Conn 6 Pin Male 72 9322 9322 Starter Base 73 9001 9001 Screw 4 74 9406 9406 Filter Carbon Kit 9406A Key 120V P N 240V P N Description 75 9614 9614 Elbow 3 8 76 48507 48507 Short Coil Brack...

Страница 17: ...Fountain Classic Owner s Manual Page 17 Exploded Drawing 48999 Three Temperature Unit...

Страница 18: ...406 Filter Carbon Kit 9406A 75 9614 9614 Elbow 3 8 Parts List Key 120V P N 240V P N Description 76 48507 48507 Short Coil Bracket 77 48508 48508 Med Coil Bracket 78 48509 48509 Tall Coil Bracket 79 72...

Страница 19: ......

Страница 20: ...Form 6338 2000 Pure Water Inc Form 6338 2000 Pure Water Inc Form 6338 2000 Pure Water Inc Form 6338 2000 Pure Water Inc Form 6338 2000 Pure Water Inc U S and Foreign Patents Pending...

Отзывы: