Step 6
Step 6
Step 6
Step 6
Step 6 Steam Sterilization of the Machine:
Steam Sterilization of the Machine:
Steam Sterilization of the Machine:
Steam Sterilization of the Machine:
Steam Sterilization of the Machine:
Use the high temperature tubing, included in the parts
kit in place of the post filter. It will connect the outlet
end of the condensing coil to the storage tank inlet.
This tube must be used because the post filter cannot
withstand the temperature of the steam. Now the
boiling chamber is creating steam. The steam will rise
up to the condensing coil. Normally the fan would
cool the steam and it would change back to water
form. The fan switch is turned off, so there is no way for the steam to cool and con-
dense. Steam will be sent to the storage tank. This will heat the tank and kill any
bacteria in the machine. Once you can see that steam is being created, allow the unit
to steam for 25 minutes. (Total time spent is approximately 1 hour.)
Step 7
Step 7
Step 7
Step 7
Step 7 Distillation:
Distillation:
Distillation:
Distillation:
Distillation:
After the unit has adequately steam sterilized,
turn the Fan switch to the ON position. The fan
will start and begin to cool the steam. After a
few minutes, distilled water will be created.
Step 8
Step 8
Step 8
Step 8
Step 8 Rinse the Post Filter:
Rinse the Post Filter:
Rinse the Post Filter:
Rinse the Post Filter:
Rinse the Post Filter:
Remove the high temperature tubing used for
Steam Sterilization. Connect the Post Filter to
the condensing coil outlet and the storage tank
inlet. There is an arrow on the side of the filter
that indicates the proper direction of the post
filter. Allow the unit to distill for 5-6 hours.
Using the spigots in the front, empty the water
from the unit. This water should be discarded.
(Three temperature unit owners:
be sure to
draw water from the hot water spigot so
any air in the lines or tank is released.
)
Step 9
Step 9
Step 9
Step 9
Step 9 Turn the dispensing unit on:
Turn the dispensing unit on:
Turn the dispensing unit on:
Turn the dispensing unit on:
Turn the dispensing unit on:
Allow the distiller to operate for an additional 5-6 hours. Several gallons of water will
be in the storage tank. It is now safe to turn the Cooler Power switch to ON, and the
Dispenser Hot Water Switch to ON.
(Three temperature unit only.)
Содержание Fountain Classic
Страница 2: ...Page 2 Fountain Classic Owner s Manual...
Страница 14: ...Page 14 Fountain Classic Owner s Manual Wiring Schematic...
Страница 15: ...Fountain Classic Owner s Manual Page 15 Exploded Drawing 48998 Two Temperature Unit...
Страница 17: ...Fountain Classic Owner s Manual Page 17 Exploded Drawing 48999 Three Temperature Unit...
Страница 19: ......