PR20.0 FLUSH  MOUNT AIR CLEANER APPLICATION 

 
 
The PR20.0 flushmount Air Cleaner is designed to drop into a suspended ceiling. It replaces 
either 1 - 2' x 4' tile or 2 - 2' x 2' tiles from the suspended ceiling. In order to install the PR20.0 
flushmount easily, the clearance above the suspended ceiling needs 
to be at least 18" and is recommended that the air cleaner is installed 
in areas that do not exceed a 13 foot ceiling height. The weight of the 
system does not rest on the ceiling grids but is secured above the 
suspended ceiling to a permanent structure such as a joist or beam. 
All filters in the PR20.0 flushmount are accessible from the louvered 
door and hinge door on the face of the system. 

1 unit recommended 

for every 2000 square feet.  

 

 

Capacity

 - Up to 2,000 Sq. Ft. 

 

2 Speed

 - High - 2,000 CFM | Low - 1,200 CFM 

 

Installation Options

 – Flushmount – fits into 

2)  2' x 2' ceiling tiles 
or 1)  2' x 4' ceiling tile 

 

Dimensions

 - 46-1/2" L x 23-3/4" W x 17" H 

 

Cabinet Construction

 - Aluminum 

 

Shipping Weight

 -135 lbs. 

 

Electrical

 - 9.2 amps | 120V 

 

Power Cord

 - 10' long | 3 prong grounded plug 

 

Three Filter System

 - Includes 1 Year Supply of Filters 

1 - 6" HEPA Filter 
1 - 6" (18 lb.) Carbon V-Bank Filter 
12 - 1/2" Pre-Filters 

 

Warranty

 - All Systems carry a lifetime Blower/Motor Warranty* 

 

Certifications - 

All electrical components and fan motor are UL Listed and CSA Certified 

 

NOTE: 18" clearance above drop ceiling required. Install by removing ceiling tile and dropping 
unit in. Plug in or hard wire. Installation hardware included. 

*Lifetime Blower/Motor warranty applies if filters are changed as required and are purchased 
from Pure n Natural Systems, Inc. 
 

 
 

For any questions, please contact our customer service department at 

1-800-237-9199

 
 

Pure n Natural Systems, Inc. 

P.O. Box 1137  

  Streamwood, IL  60107 

Toll-Free – 1-800-237-9199  

  Fax – 847-470-1686 

www.purennatural.com

 

Содержание PR20.0

Страница 1: ...k filter The intake door is located closest to the HI OFF LO switch on the face of the system Unclip the two latches on the intake door and the door will swing down The Pre Filter is the first filter behind the intake door Peel away dirty Pre Filter and discard Install the new Pre filter with the white side out Close door DO NOT WASH PRE FILTERS Step 2 The carbon filter is located behind the Pre F...

Страница 2: ...system will fit into either one 2 x 4 or two 2 x 2 tiles Step 4 A system being installed into a drop ceiling that has joints steel girders or exposed beams above can be hung without the eye lags see step 5 At least one eye lag will be needed if your system is being installed into a ceiling that is solid above see step 6 Step 5 Locate either a joist girder or beam that is directly above the tile wh...

Страница 3: ... grid work of the drop ceiling After you have adjusted the weight of the system on the grid work then loop the wire and twist tightly Step 7 After the system is installed put your H E P A filter back into the system Make sure the H E P A filter is snug Replace the H E P A bar and the adjustable louver door For any questions please contact our customer service department at 1 800 237 9199 ...

Страница 4: ...M Installation Options Flushmount fits into 2 2 x 2 ceiling tiles or 1 2 x 4 ceiling tile Dimensions 46 1 2 L x 23 3 4 W x 17 H Cabinet Construction Aluminum Shipping Weight 135 lbs Electrical 9 2 amps 120V Power Cord 10 long 3 prong grounded plug Three Filter System Includes 1 Year Supply of Filters 1 6 HEPA Filter 1 6 18 lb Carbon V Bank Filter 12 1 2 Pre Filters Warranty All Systems carry a lif...

Отзывы: