background image

INSTALLATION OF PR20.0 AIR CLEANER 

 

 

EQUIPMENT: 

 

1.

 

Each PR20.0 unit is equipped with two (2) eye bolts, two (2) eye lags and industrial 
hanging wire for easy installation. 

 
2.

 

The PR20.0 has a ten foot power cord and a three prong grounded plug. Electrical:  120 
Volts, 9 Amps. 

 

3.

 

Each unit includes a years supply of filters, which consists of twelve (12) pre-filters, one 
(1) V-Bank charcoal filter and one (1) H.E.P.A. filter. 

 
 

INSTALLATION: 

 

Step 1

. Remove the system from the shipping container. Remove the adjustable louver door 

from inside the system. After you have removed the adjustable louver door, remove the 
industrial staples and the H.E.P.A. bar and then slip out the H.E.P.A. filter. The H.E.P.A. filter is a 
pleated media surface with a particle board frame. Removing the H.E.P.A. filter will make the 
system lighter for installation purposes. 
 

Step 2

. On either side of the system there are two mounting holes where the eye bolts are 

inserted. It is easiest to screw the eye bolts into these mounting holes before mounting into the 
ceiling. If the area above the drop ceiling is tight for space, then you may need to put the eye 
bolts in the mounting holes after you have the system into the drop ceiling. 
 

Step 3

. Remove the ceiling tile(s). The system will fit into either one 2’x 4’ or two 2’x 2’ tiles. 

 

Step 4

.  A system being installed into a drop ceiling that has joints, steel girders or exposed 

beams above can be hung without the eye lags (see step 5). At least one eye lag will be needed 
if your system is being installed into a ceiling that is solid above (see step 6). 
 

Step 5

.  Locate either a joist, girder or beam that is directly above the tile where your system will 

be installed.  After you have located a joist, girder or beam, drape the industrial hanging wire 
over the apparatus so that either side is evenly dispersed. Line up the eye bolts with the hanging 
wire so they are vertical. Thread one end of the hanging wire through one of the eye bolts, loop 
the wire and twist tightly together. Thread the opposite end of the hanging wire through the 
opposite eye bolt. Pull the wire tight. The system should be only slightly resting on the grid work 
of the drop ceiling. After you have adjusted the weight of the system on the grid work, then loop 
the wire and twist tightly together. 
 

Step 6

.  Locate a stud in the solid ceiling that is directly above the tile where the system will be 

installed. Fasten the eye lag into the stud making sure to line up the eye lag with the eye bolts 
on the system so the hanging wire will hang vertically. Thread the hanging wire through the eye 
lag so that either side is evenly dispersed. Thread one end of the hanging wire through one eye 

Содержание PR20.0

Страница 1: ...k filter The intake door is located closest to the HI OFF LO switch on the face of the system Unclip the two latches on the intake door and the door will swing down The Pre Filter is the first filter behind the intake door Peel away dirty Pre Filter and discard Install the new Pre filter with the white side out Close door DO NOT WASH PRE FILTERS Step 2 The carbon filter is located behind the Pre F...

Страница 2: ...system will fit into either one 2 x 4 or two 2 x 2 tiles Step 4 A system being installed into a drop ceiling that has joints steel girders or exposed beams above can be hung without the eye lags see step 5 At least one eye lag will be needed if your system is being installed into a ceiling that is solid above see step 6 Step 5 Locate either a joist girder or beam that is directly above the tile wh...

Страница 3: ... grid work of the drop ceiling After you have adjusted the weight of the system on the grid work then loop the wire and twist tightly Step 7 After the system is installed put your H E P A filter back into the system Make sure the H E P A filter is snug Replace the H E P A bar and the adjustable louver door For any questions please contact our customer service department at 1 800 237 9199 ...

Страница 4: ...M Installation Options Flushmount fits into 2 2 x 2 ceiling tiles or 1 2 x 4 ceiling tile Dimensions 46 1 2 L x 23 3 4 W x 17 H Cabinet Construction Aluminum Shipping Weight 135 lbs Electrical 9 2 amps 120V Power Cord 10 long 3 prong grounded plug Three Filter System Includes 1 Year Supply of Filters 1 6 HEPA Filter 1 6 18 lb Carbon V Bank Filter 12 1 2 Pre Filters Warranty All Systems carry a lif...