CLEANAIR CA-1000 ELECTRONIC AIR CLEANER

 

READ AND SAVE THESE INSTRUCTIONS 

 

It is highly recommended that a licensed electrician or licensed contractor install these units.

  

This manual contains information for location, installation, operation and service. Before 

installation and operation of the air cleaner, read instructions carefully to ensure safe and 
effective operation of this unit, and avoid unnecessary service cost. 

Carefully unpack unit and check for damage incurred in shipment. Report any damage to freight 

line immediately.  

Proper installation procedures for both T-BAR ceiling and flush mount installation are provided. 

Follow method that best suites application for air cleaner.  

The unit cover is hinged, to allow for easy access 

and serviceability of the air cleaner components. 
Two (2) spring latches are located on front of cover 
as shown in Fig. l. To gain access to inside of air 
cleaner unit for installation and servicing, depress 
both latches simultaneously and swing cover open. 

T-BAR INSTALLATION 

Installation requires a 10” clearance be­tween permanent ceiling and T

-Bar ceiling. CAUTION: 

Do not install unit in a T-Bar ceiling unless unit can be secured to a permanent ceiling or ceiling 
joists, as described. 

Installer must provide the following items for securing unit: 

 

Four (4) 1/4-

20 x 1” Eyebolts

 

 

Four (4) 1/4-20 Hex Nuts 

 

Four (4) 1/4 Flat Washers 

 

Length required - 2/0 Chain 

 
Open unit cover and remove cell assembly. (It is 
necessary to remove thumb nut in the housing to 
allow cell to slide into position for removal.) Install 
eyebolts in cabinet top as shown in Fig. 2.  