15
Note) Router ID is associated with commend control Protocol; therefore, it is important to remember
Matrix Router's current Router ID.
h
RS232
- There are four values those need to be set for serial communication; baud rate, data bits, stop bits,
and parity. Click and select each value using touch screen and push enter button to save.
Factory default (recommended) settings for serial communication are:
x
Baud rate - 19200
x
Data bits - 8
x
Parity - none
x
Stop bits - 1
x
Flow control
–
none
and supported settings are:
Supported Baud Rate:
4800 Bps, 9600 Bps, 14400 Bps, 19200 Bps, 38400 Bps,
57600Bps, 76800 Bps, 115200 Bps
Supported Data bit:
5 bit, 6 bit, 7 bit, 8 bit
Supported
Parity:
Non,
Even,
Odd
Supported Stop bit:
1 bit, 2 bit
h
LAN
- HX series Matrix Router can be controlled through the 10/100 base Ethernet port using a command
line interface.
There are four values that need to be set for LAN communication; IP address, Gateway address,
Subnet mask, and Mac address. Please use below button indication to configure LAN settings;
(For HX-8800-U, HX-8400-U, HX-8200-U):
*
Input
#1
:
1
*
Output
#1
:
9
*
Input
#2
:
2
*
Output
#2
:
0
*
Input
#3
:
3
* Input #4 :
4
* Input #5 :
5
* Input #6 :
6
* Input #7 :
7
* Input #8 :
8