© PumpSpy Technology, LLC Questions?
Email Tech Support:
1. Install the Backup Pump using good plumbing practices. Both the Primary and
Backup pumps should set on the bottom of the basin.
2. Install the switches for the primary pump and backup pump. The ON level of
the lowest backup switch should be approximately 1” - 2” higher than the ON
level of the primary sump pump.
3. Connect the Backup Sump Pump to the PumpSpy
™
Controller’s white jack.
4. Connect the backup switches to the PumpSpy
™
Controller’s color coded jacks.
5.
VERY IMPORTANT! Connect the Main Sump Pump to the AC outlet on the
PumpSpy
™
controller.
6. Open the battery case and place 12 Volt battery inside.
7. Connect the PumpSpy
™
controller to the battery. Black to – (negative), Red to
+ (positive). Replace and lock lid onto battery case.
8. Plug the PumpSpy
™
controller into an AC outlet. Consult your local codes for
GFCI requirements.
9. The PumpSpy
™
system will initialize and boot up. After booting, MAIN PUMP,
BACKUP PUMP & WIFI should be YELLOW. WATER LEVEL, POWER &
BATTERY should be GREEN. MAIN PUMP & BACKUP PUMP will turn GREEN
after a successful test cycle.
TEST THE SYSTEM IN THIS ORDER! PUMPSPY RECOMMENDS
RUNNING INITIAL CYCLES WITH WATER AND CHECK ALL
PLUMBING FOR LEAKS DURING TESTING.
Lift the lowest Battery Backup switch and hold. Release when the battery backup
pump cycles. BACKUP PUMP will turn GREEN. MAIN PUMP will turn RED and
the alarm will sound. Press ALARM MUTE to silence, if desired.
REFILL BASIN WITH WATER.
Cycle the Primary Sump Pump. The alarm will stop and MAIN PUMP will be green.
WIFI will turn GREEN after the completing the WiFi setup with the PumpSpy app.
1
2
3
4
5
6
7
8
9
CONNECTING THE PUMPSPY CONTROLLER