PumpSpy PS2000 Скачать руководство пользователя страница 2

© PumpSpy Technology, LLC   Questions? 

Email Tech Support:

 [email protected]

SAFETY FIRST!

WARNING

WARNING INDICATES A POTENTIALLY 

HAZARDOUS SITUATION WHICH, IF NOT 

AVOIDED, COULD RESULT IN DEATH, SERIOUS 

INJURY OR MAJOR PROPERTY DAMAGE.

This instruction manual contains very important information for you to know and understand. This 

information is provided for your safety and to help prevent equipment problems from occurring. Please 

observe all safety information labeled danger, warning and caution.

RISK OF ELECTRIC SHOCK. TO REDUCE THIS RISK, OBSERVE THE 

FOLLOWING WARNINGS:

WARNING!   To reduce the risk of electrical shock, this system must be properly grounded in accordance with the 

National Electric Code (NEC) and all applicable state and local codes and ordinances. The receptacle 
should be protected with a Ground Fault Circuit Interrupter (GFCI).

WARNING!   To reduce the risk of electrical shock, always disconnect the pump / system from the power source 

and battery BEFORE handling or servicing.

WARNING!  Never remove the ground prong from the plug, or use an adapter that eliminates the ground prong.

WARNING!  Never plug this pump system into an electric outlet while standing on a wet surface.

WARNING!   Cables should be protected at all times to avoid punctures, cuts and abrasions that may result in 

exposed wiring. Never handle connected power cords with wet hands.

WARNING!   The PumpSpy

 System has not been investigated for use in or around swimming pools, marine areas, 

recreational water installations, decorative fountains or any installation where human contact with the 

pumped fluid is common. 

WARNING!   Do not use an extension cord. Extension cords could present a safety hazard if not properly sized, 

become damaged or the connection falls into the sump pit. Do not attempt to disassemble the 

PumpSpy controller or Backup Pump. There are no field serviceable parts or repair options! 

RISK OF EXPLOSION. TO REDUCE THIS RISK, OBSERVE THE FOLLOWING 

WARNINGS:

WARNING!

  Do not use to pump flammable or explosive liquids such as gasoline, fuel oil, kerosene, etc. 

WARNING!  

Do not use in a flammable or explosive atmosphere. 

NOT SUITED FOR POTABLE WATER APPLICATIONS. 

WARNING!   Do not use this pump to transfer water that will be used for potable (drinking) 

water. This pump is only to be used in applications for which it is designed.

CAUTION INDICATES A POTENTIALLY HAZARDOUS 

SITUATION WHICH, IF NOT AVOIDED, MAY RESULT 

IN MINOR INJURY OR PROPERTY DAMAGE.

CAUTION

TO REDUCE THE RISK OF HAZARDS THAT CAN CAUSE INJURY 

OR PROPERTY DAMAGE, OBSERVE THE FOLLOWING WARNINGS:

CAUTION!   Do not use discharge hose. Discharge hose may whip under pressure. Use rigid piping 

and fittings to secure the pump in the sump basin to reduce movement.

CAUTION! Do not install the pump if it has been damaged in any way. 
CAUTION! Do not carry or lift the pump by the power cord. Use the pump’s lifting handle.

Содержание PS2000

Страница 1: ...id State Pump Controller Power Supply Requirements 12VDC Motor Brushless DC AMP Rating 18 Amps Temperature Rating 40 F to 120 F Discharge 1 1 2 NPT MAX Flow 3000 GPH Power Supply Requirements 120VAC 60 Hz 15 AMP Electrical Ratings 12Amps 120VAC 18 Amps 12VDC Relative Humidity 0 to 80 Storage Temperature 0 to 70 C Operating Temperature 0 to 50 C SPECIFICATIONS PumpSpy PS2000 PumpSpy Technology supp...

Страница 2: ...nected power cords with wet hands WARNING The PumpSpy System has not been investigated for use in or around swimming pools marine areas recreational water installations decorative fountains or any installation where human contact with the pumped fluid is common WARNING Do not use an extension cord Extension cords could present a safety hazard if not properly sized become damaged or the connection ...

Страница 3: ...gure 1 1 The backup pump has a 1 1 2 in NPT discharge 2 Cut a 3 ft section of 1 1 2 in rigid PVC pipe Glue 1 1 2 in pipe to a threaded fitting 3 Screw pipe from step 2 into pump discharge 4 Place the pump with the 3 ft section of PVC pipe on a solid level surface in the sump pit Do NOT place the pump on a loose or sandy surface Small stones or sand may damage the pump resulting in pump failure 5 A...

Страница 4: ... pump as shown in illustration for Method 2 8 Glue a short piece of PVC pipe between the 45º elbow and the Y THE CHECK VALVES FOR BOTH PUMPS MUST BE INSTALLED BELOW THE Y FITTING The remainder of the discharge pipe installation will vary depending on individual circumstances Using sound plumbing practices route the discharge pipe to an exterior wall by the shortest distance AFTER PLUMBING IS COMPL...

Страница 5: ...e Red to positive Replace and lock lid onto battery case 8 Plug the PumpSpy controller into an AC outlet Consult your local codes for GFCI requirements 9 The PumpSpy system will initialize and boot up After booting MAIN PUMP BACKUP PUMP WIFI should be YELLOW WATER LEVEL POWER BATTERY should be GREEN MAIN PUMP BACKUP PUMP will turn GREEN after a successful test cycle TEST THE SYSTEM IN THIS ORDER P...

Страница 6: ... yellow setup mode If the WiFi LED is not yellow gently press and hold the WiFi setup button using a pencil paper clip The unit will turn yellow enter setup mode after 3 seconds STEP 4 Connect to the PumpSpy System On your Apple Android device open Settings Select WiFi Select the WiFi network named PumpSpy Press the home button on your Apple Android device STEP 5 Enter your WiFi Network Credential...

Страница 7: ... dark and a message will be displayed Close your browser Your PumpSpy devices Wi Fi indicator will turn red for several seconds then green once successfully connected to PumpSpy s servers If it stays red after 60 seconds start over Make sure you enter the correct Wi Fi password Once the Wi Fi indicator is green open the PumpSpy app and select Connect Device Manually Enter your PumpSpy device s 15 ...

Страница 8: ... warranty service cost of shipping will be paid one way This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of PumpSpy products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This warranty shall be governed and construed under the laws of the state of Ohio The warranty period will not be extended by ...