3.3.  Acoustic indication. 

 

A collective failure is indicated by the piezoelectric indicator, 1 beep every second. The acoustic indication 

can be turned off by changing the ON / OFF position of the switch  . 
 

                                                       

 

switch in the up position, indication ON

 

 

switch in the down position, indication OFF 

 
 
4.  Operation and use. 
 

4.1.  Overload or short circuit of the PSU output. 

The AUX1 ÷ AUX16 power supply outputs are protected against short circuit by melting fuses; in the case 

of fuse failure, it should be replaced with a fuse of the same type.  

 
4.2.  Maintenance. 

             Any and all maintenance operations may be performed following the disconnection of the PSU from the 
power supply network. The PSU   does not require performing any specific maintenance measures. In case of fuse 
replacement, use a replacement of the same parameters.  

 

 

 

 

WEEE LABEL 

 

Waste electrical and electronic equipment must not be disposed of with normal household 

waste. According to the European Union WEEE Directive, waste electrical and electronic 

equipment should be disposed of separately from normal household waste. 

 

 

 

 
 
 
 

 

 
 
 
 
 
 
 

 

Pulsar  

Siedlec 150,  32-744 Łapczyca, Poland 

Tel.  (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

E-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

Содержание R1624T

Страница 1: ...R1624T v 1 0 R 24V 16x0 5A TOPIC RACK mounted power supply EN Edition 1 from 22 09 2017 Supercedes the edition...

Страница 2: ...r loss activation of the output fuse in the camera power supply circuit too high temperature of the PSU 70 C the PSU failure protections SCP short circuit protection OVP overvoltage protection overvol...

Страница 3: ...unting in standard RACK 19 cabinets 1 2 Block diagram Fig 1 The block diagram of the PSU 1 3 Description of PSU components and connectors Table 1 Components of the front panel of the power supply Elem...

Страница 4: ...www pulsar pl R1624T RACK POWER 4 Fig 2 The front power of the power supply unit Fig 3 The view of the PSU...

Страница 5: ...s tab 3 Enclosure dimensions W 19 H 2U 482 x 88 x 223 mm WxHxD Fixation four point butt mounting to RACK profiles the set include 4 M6 screws cage nuts Net weight 5 4kg 5 9kg Enclosure Steel plate RAL...

Страница 6: ...rmed about the method of unplugging usually through assigning an appropriate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure 1 Before...

Страница 7: ...re of the switch mode power supply GREEN LED on DC voltage in the AUX1 AUX16 output off no DC voltage in the AUX1 AUX16 output 3 2 Technical output The power supply is fitted with the ALARM output of...

Страница 8: ...ed with a fuse of the same type 4 2 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network The PSU does not require perfor...

Отзывы: