background image

www.pulsar.pl 

 

 

 

 

PSBOC30012200   

 

 

 

 
 

 

                          

WEEE MARK 

 

 

According  to  the  EU  WEE  Directive  –  It  is  required  not  to  dispose  of  electric  or 

electronic waste as unsorted municipal waste and to collect such WEEE separately.

 

 
 

 

 

The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled 

according to the applicable law.

 

 

 

 
 
 
 

 

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pulsar  

Siedlec 150,  32-

744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

GENERAL WARRANTY CONDITIONS 

 
1. Pulsar (the manufacturer) grants a two-year warranty for the equipment, counted from the device’s production date. 

2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the 

manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects, unless such 
defects have been reported within the warranty period (item 1).  

3. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main office of the 
manufacturer.  

4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the defect.   
5. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenienve, however 

not later that within 14 days from the delivery to the service centre of the manufacturer.  
6. The repair period mentioned in item 5 may be prolonged, if there are no technical possibilities to carry out the repairs, or if the 

equipment has been conditionally accepted, due to the breaking warranty terms by the claimant.  
7. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, exclusively.  

8. The warranty does not cover the defects of the equipment, resulting from: 
- reasons beyond the manufacturer's control, 

- mechanical damage, 
- improper storage and transport, 

- use that violates the operation manual or equipment’s intended use 

- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,  
- improper installation and configuration (in defiance with the manual), 

9. The warranty is void in any of the following circumstances: 
- construction changes  

- repairs carried out by any unauthorized service center 
- damage or removal of warranty labels 

- modifications of the serial number 
10. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined according to the 

wholesale prices suggested by the manufacturer on the day of purchase.  
11. The manufacturer takes no reponsibility for the defects that result from:  

- the damaging, malfunctioning or inability to operate the equipment 
- defects that result from using the equipment outside its stated specifications and operating parameters failing to abide by the 

recommendations and requirements contained in the manual, or the use of the equipment.  

 

Содержание PSBOC30012200

Страница 1: ...PSBOC30012200 v 1 0 PSBOC 13 8V 20A OC Enclosed buffer switch mode power supply unit with technical outputs EN Edition 2 from 01 06 2016 Supercedes edition 1 from 09 04 2015...

Страница 2: ...ONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure...

Страница 3: ...relay type 6 LoB output indicating battery low voltage relay type 7 EPS AC absence technical output OC type 8 PSU output indicating DC absence PSU failure OC type 9 LoB output indicating battery low v...

Страница 4: ...table Short circuit protection SCP electronic automatic recovery Overload protection OLP 105 150 of power supply automatic recovery Battery circuit protection SCP and reverse polarity connection melti...

Страница 5: ...y a qualified installer holding relevant permits and licenses applicable and required for a given country for 230V AC interference and low voltage installations The unit should be mounted in confined...

Страница 6: ...view of the PSU 3 Operating status indication 3 1 LED indication The PSU is equipped with 3 LEDs on the PCB board red LED Fig 2 element 1 normal status AC power permanently illuminated AC power absenc...

Страница 7: ...nected to ground L level 0V In case of decrease of battery voltage UBAT 11 5V the output is switched into high impedance state hi Z relay output In case of a battery voltage drop UBAT 11 5V the contac...

Страница 8: ...ays from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equi...