Pulsar IMP Lite 10 Скачать руководство пользователя страница 3

IMP

 

Lite

 

(F

IRST EDITION REVISION 

4) 

February 2020 

Part Number M-082-0-001-4P  

C

OPYRIGHT 

 

© Pulsar Process Measurement Limited, 2005-20. All rights reserved. No part of this publication may 
be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in 
any form without the written permission of Pulsar Process Measurement Limited. 

W

ARRANTY AND 

L

IABILITY

 

Pulsar Process Measurement Limited guarantee for a period of 2 years from the date of delivery that it 
will  either  exchange  or  repair  any  part  of  this  product  returned  to  Pulsar  Process  Measurement 
Limited if it is found to be defective in material or workmanship, subject to the defect not being due to 
unfair wear and tear, misuse, modification or alteration, accident, misapplication or negligence. 

D

ISCLAIMER

 

Pulsar Process Measurement Limited neither gives nor implies any process guarantee for this product 
and  shall  have  no  liability  in  respect  of  any  loss,  injury  or  damage  whatsoever  arising  out  of  the 
application or use of any product or circuit described herein. 

Every  effort  has  been  made  to  ensure  accuracy  of  this  documentation,  but  Pulsar  Process 
Measurement Limited cannot be held liable for any errors. 

Pulsar Process Measurement Limited operates a policy of constant development and improvement and 
reserves the right to amend technical details as necessary. 

 

C

OMMENTS

,

 

S

UGGESTIONS AND 

T

ECHNICAL 

E

NQUIRIES

 

Please contact Pulsar Measurement if you have any comments, suggestions or if you require technical 
support using the information below: 

 

UK Office 

Canada Office 

USA Office 

Pulsar Process Measurement Ltd. 

Cardinal Building 

Enigma Business Centre 
Sandy’s Road 
Malvern 

Worcestershire 

WR14 1JJ 

United Kingdom 

Greyline Instruments Inc. 

16456 Sixsmith Drive 

Long Sault 

ON 

K0C 1P0 

Canada 

Greyline Instruments Inc. 

11451 Belcher Road South 

Largo 

FL 33773 

USA 

Tel:  +44 (0) 1684 891371 
Fax: +44 (0) 1684 575985 

Tel: 
Toll Free: 
Fax: 

613-938-8956 
855-300-9151 
613-938-4857 

Tel: 
Tax Free: 
Fax: 

315-788-9500 
888-473-9546 
315-764-0419 

Website:  

www.pulsar-pm.com

  

General Information email: 

[email protected]

 

Technical Support email: 

[email protected]

  

Website: 

www.greyline.com

  

General Information email: 

[email protected]

  

Technical Support email: 

[email protected]

  

Website: 

www.greyline.com

  

General Information email: 

[email protected]

  

Technical Support email: 

[email protected]

  

 

 

Содержание IMP Lite 10

Страница 1: ...IMP Lite INSTRUCTION MANUAL...

Страница 2: ......

Страница 3: ...n made to ensure accuracy of this documentation but Pulsar Process Measurement Limited cannot be held liable for any errors Pulsar Process Measurement Limited operates a policy of constant development...

Страница 4: ......

Страница 5: ...faults 14 Factory Defaults 14 IMPLITE 15 Setting up Your Application 15 Empty Distance 15 Span 15 Near and Far Blanking 15 Using the 4 20 mA Output 15 Setting Security Passcodes 16 Using A Passcode 16...

Страница 6: ...ent reading this operating manual will ensure that your installation is as simple as possible About this Manual It is important that this manual is referred to for correct installation and operation T...

Страница 7: ...tilises state of the art echo extraction technology The IMP Lite comes in three models Lite 3 with a range from 0 20m 0 66 feet to 3 00m 9 84 feet Lite 6 with a range of 0 3m 0 98 feet to 6 00m 19 69...

Страница 8: ...Hz Range Lite 3 0 2 3m 0 66 10ft Lite 6 0 3 6m 0 98 20ft Lite 10 0 3 10m 0 98 33ft Digital echo processing Current output 3 5 22mA Accuracy 0 25 or 6mm 0 24 inches whichever is greater Resolution 0 1...

Страница 9: ...Page4 EU Declaration of Conformity...

Страница 10: ...ns such as pipes beams etc The IMP 3 should be mounted at least 20cm 0 66 feet above the maximum level of the material and be perpendicular to the surface Whilst the IMP 6 and 10 should be mounted at...

Страница 11: ...Page6 Dimensions The dimensions of the IMP Lite are as shown below 1 5 BSP NPT IMP Lite 3 6 2 BSP NPT IMP Lite 10...

Страница 12: ...Lite 3 3 metres 9 84 feet 200mm 0 66 feet Lite 6 6 metres 19 69 feet 300mm 0 98 feet Lite 10 10 metres 32 18 feet 300mm 0 98 feet L should as a minimum be at least that as detailed in the table above...

Страница 13: ...is clear of any obstructions such as weld seams gaskets etc in order to avoid unwanted signal returns If using standpipes which extend into the vessel beyond the blanking distance but not as far as th...

Страница 14: ...d with a suitable gland to ensure moisture protection is maintained Terminal Connection Details Wiring details are also given on the terminals under the access cover Terminal Connections Terminal 1 ve...

Страница 15: ...5 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Supply Voltage Total Cable resistance Maximum cable resistance vs supply voltage for 2 wire mode Important Information If the equipment is installed or u...

Страница 16: ...Program Mode Run Mode This mode is used once the IMP Lite has been set up in program mode It is also the default mode that the unit reverts to when it resumes operation after a power failure When the...

Страница 17: ...Parameter Value How to Access Program Mode To access the Program mode press the ESC and Enter button simultaneously where upon the display will show PASS on the LCD display briefly to prompt you to en...

Страница 18: ...enu Once you have reached the relevant menu scroll through the parameters and enter the necessary information To enter the information use the UP and DOWN keys to increment or decrement the digit and...

Страница 19: ...o the material surface It will be indicating in P104 Measurement Units as shown on the display TIP In some applications it is simplest to empty the vessel take a reading from the Imp for distance and...

Страница 20: ...of empty level If you wish to monitor further than the empty level then increase this figure so that the empty level plus the far blanking figure as of empty level is greater than the surface being m...

Страница 21: ...as follows Additional Information The passcode is also used for remote access using the RS232 so if this is being used be sure to ensure any additional equipment using this feature is changed accordin...

Страница 22: ...t or the current level of software in your IMP Lite whilst in Run Mode press the ESC button and the serial number along with the software revision will be displayed Alternatively enter Program Mode an...

Страница 23: ...Page18 This page left blank intentionally...

Страница 24: ...shows volume of material in the vessel P104 Measurement Units This parameter sets the units you want to use for programming and display Option Description 1 metres All units of measure are METRES 2 c...

Страница 25: ...version of IMP Lite being used It should not be set to less than this figure but can be increased IMP Lite Version Near Blanking Distance Lite 3 metre Default Blanking Distance 0 2m 0 66 feet Lite 6...

Страница 26: ...03 Vessel Shape P600 Value Dimensions Required P600 0 Cylindrical Flat base Default Cylinder diameter P600 1 Rectangular Flat base Width and Breadth P600 2 Cylindrical Cone base Cylinder diameter and...

Страница 27: ...tom P600 8 Horizontal cylinder with flat ends Cylinder diameter and tank length P600 9 Horizontal cylinder with parabolic ends Cylinder diameter length of one end section and tank length P600 10 Spher...

Страница 28: ...ed P600 5 Cylindrical Half sphere base Cylinder Diameter Not Used Not Used P600 6 Cylindrical Flat sloped base Height of base Cylinder Diameter Not Used P600 7 Rectangular Flat sloped base Height of b...

Страница 29: ...UK Gallons 6 US Gallons Volume will be totalised in US Gallons 7 Cubic feet Volume will be totalised in cubic feet 8 Barrels Volume will be totalised in barrels P606 Correction Factor This parameter i...

Страница 30: ...last known values until a valid reading is obtained If required then you can change this so that the unit goes to high 100 of span or low empty as follows Option Description 1 Known Default Remain at...

Страница 31: ...d result on the device that is connected P839 mA High Trim If the device you are connected to is not calibrated and not showing the high value then you can trim it using this parameter You can either...

Страница 32: ...of the temperature measurement By default it is set to internal transducer P852 1 which will automatically detect the temperature from the transducer If for any reason no temperature input is receive...

Страница 33: ...several times then adjust the Sound Velocity accordingly to obtain an accurately displayed reading Gas Sound Velocity Chlorine 206 m sec Argon 308 m sec Oxygen 316 m sec Air 331 5 m sec Ammonia 415 m...

Страница 34: ...e Default 10 000 metres minute 32 81 feet minute System SyS1 Menu The following three parameters do not affect how the unit performs but details contained in them may be required by Pulsar when making...

Страница 35: ...Menu P991 Hard Test When this parameter is selected the unit will test the following in turn Display All the segments on the LCD and the backlight are lit up so you can see if they all work Press the...

Страница 36: ...of range sensor is perpendicular to material surface Incorrect reading being displayed for current level Measure actual distance from transducer face to surface of material Enter Program Mode and acce...

Страница 37: ...sducer in accordance with regional environmental regulations for electrical electronic products Controllers Remove power disconnect the Controller and remove battery if fitted Dispose of Controller in...

Страница 38: ...Page33...

Отзывы: