P605 Volume Units
This parameter determines the units that will be used in calculating volume
conversion. It is used in conjunction with
P607
(
maximum volume
), please
note that there is no provision for the volume unit’s descriptor to be shown on
the display.
The choices are:
Option
Description
0 = No Units
Volume will be totalised with
no units
1 = Tons
Volume will be totalised in
Tons
2 = Tonnes
Volume will be totalised in
Tonnes
3 = Cubic metres
Volume will be totalised in
cubic metres
4 = Litres
Volume will be totalised in
litres
5 = UK Gallons
Volume will be totalised in
UK Gallons
6 = US Gallons
Volume will be totalised in
US Gallons
7 = Cubic feet
Volume will be totalised in
cubic feet
8 = Barrels
Volume will be totalised in
barrels
P606 Correction Factor
This parameter is used to enter a correction factor, when required, such as the
specific gravity of the material so that the volume calculated is relative to the
actual amount of material that can be contained between
empty level
(
P105)
and 100% of
span
(
P106). Default = 1
P607 Max Volume
This parameter displays the actual maximum volume that has been calculated
by the
IMP Lite
, i.e.
P604 Calculated Volume x P606 Correction Factor
,
and is a Read Only parameter. The volume displayed will be shown in
P605
Volume Units
and is the total volume available between
empty level
(
P105)
and 100% of
span
(
P106
).