1.3 Description of components and power supply terminals (Table 1, Fig.2). 
 

Table 1. Components of the Power supply PCB (Printed Circuit Board) (see Fig. 2). 

Component 

no. 

Description 

 

P

BAT 

Jumper 

– configuration of discharged battery disconnection system (UVP)  

 

P

BAT

 = 

 discharged battery disconnection system OFF 

 

P

BAT

 = 

  discharged battery disconnection system ON 

 

T

AC

 Jumper

- setting the delay time for AC power failure indication 

 

T

AC

 = 

  delay time T= 60s 

 

T

AC

 = 

  delay time T= 10s 

Description: 

 jumper on, 

  jumper off

 

 

START

 button (running the PSU from the battery) 

 

V

ADJ

 potentiometer,

 

DC 

12 ÷ 14,5V voltage adjustment 

 

F

BAT

 

fuse in the battery circuit, F3,15A / 250V 

 

Terminals: 
~AC~    

– AC power input 

EPS 

– technical output of AC power failure indication 

 

 

hi-Z state 

= AC power failure 

 

 

 

0V state  

= AC power - O.K. 

PSU

  

– technical output of PSU failure indication 

 

 

hi-Z state 

= failure 

 

 

0V state  

= PSU status O.K.

  

LoB

 

– technical output of low battery voltage indication 

 

 

hi-Z state 

= battery voltage U

BAT

 <11,5V 

 

 

0V state 

= battery O.K.  

+BAT-   

 

terminals for battery connection 

+AUX-  

– DC power output, (+AUX= +U, -AUX=GND) 

Description: hi-Z 

– high impedance, 0V – connection to the ground GND 

 

LEDs  

– optical indication:

 

AC  

– AC power

  

LB  

– battery charging 

AUX  

– output voltage DC 

 

Optional, external optical indication output terminal

 

 

I

BAT 

Jumper; 

- battery charging current configuration 

 

I

BAT

 = 

,  Ibat =0,2 A 

 

I

BAT

 = 

,  Ibat =0,5 A 

Description: 

 jumper on, 

  jumper off 

 

 

Fig. 2. The view of the Power supply PCB. 

 
 
 
 
 

Содержание Blue Power PSBS 2012B

Страница 1: ...PSBS 2012B v 1 0 PSBS 13 8V 2A 7Ah OC Buffer switch mode power supply unit with technical outputs EN Edition 4 from 03 11 2016 Supercedes edition 3 from 01 06 2016...

Страница 2: ...ate TABLE OF CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of components and connectors 1 4 Technical parameters 2 Installation 2 1 Requirements 2 2 Instal...

Страница 3: ...8V 4x0 5A MPSBS 7Ah PSBS 2012B LB4 4x0 5A AWZ574 AWZ576 MPSBS 7Ah 4 Buffer power supply PSBS 13 8V 12V 2A MPSBS 7Ah PSBS 2012B RN250 13 8V 12V MPSBS 7Ah 5 Buffer power supply PSBS 13 8V 12V 2x1A MPSB...

Страница 4: ...ustment FBAT fuse in the battery circuit F3 15A 250V Terminals AC AC power input EPS technical output of AC power failure indication hi Z state AC power failure 0V state AC power O K PSU technical out...

Страница 5: ...Isolation transformer Printed Circuit Board see Table 1 Fig 2 TAMPER micro switch of tamper protection NC FMAINS fuse in the power supply circuit 230V T500mA 250V L N power supply connector 230V AC PE...

Страница 6: ...rrent limitation the FBAT melting fuse failure requires fuse replacement Surge protection varistors Deep discharge battery protection UVP U 10V 0 5V disconnection of battery terminal Tamper protection...

Страница 7: ...tween input circuit and output or protection circuit 100 M 500V DC Table 6 Operation parameters Environmental class II Operating temperature 10 C 40 C Storing temperature 20 C 60 C Relative humidity 2...

Страница 8: ...icating AC power failure PSU technical output indicating PSU failure LoB technical output indicating low battery voltage Optional installation of the MPSBS relay module changing technical outputs of t...

Страница 9: ...hort circuit at the output Output overload DC DC voltage converter failure Under voltage protection activation LoB output indicating low battery voltage The output indicates low battery voltage Under...

Страница 10: ...ltage at the battery terminals drops below 10V 0 5V during battery assisted operation the batteries will be disconnected The battery protection is on when the PBAT jumper is off Caution It is not reco...

Отзывы: