background image

   

General view of the menu
Tab 1 

 

 

 

 

Tab 2

Menu    

General Setting

Menu    

Mode

PIP

Off

Hot White

Automatic

10

Calibration 

Mode

 

џ

Select the  

 

 'Calibration Mode' option.

Selection of calibration mode There are three calibration modes: manual, semi-automatic 

and automatic.

Manual calibration. Close the lens cap before beginning calibration. 

џ

Press and hold the Menu button (3) to enter the menu.

џ

A short press of the Menu button (3) opens the submenu.

џ

A short press of the Menu button (3) confirms the selection.

Automatic

Calibration requirements in the automatic mode are determined programmatically, with the 
calibration process being started automatically.

Semi-automatic

The  user  independently  sets  the  calibration  requirements  (according  to  the  image  being 

observed).

Manual

џ

Select one of the calibration modes described below with the UP (4) / DOWN (2) buttons. 

MAIN MENU FUNCTIONS

џ

Press the UP (4) / DOWN (2) buttons to move through the menu functions.

џ

Automatic exit from the menu occurs after 10 seconds of inactivity.

џ

When exiting the menu, the cursor location (    ) is remembered only for the duration of the one working session 

(i.e. until the device is powered off). The next time the device is powered on and the menu is accessed, the cursor 

will be at the first item on the menu.

џ

Menu navigation is be means of scrolling. When the last item on the first tab is reached, navigation moves to 

the first item of the second tab. 

џ

To exit the menu, press and hold down the Menu button (3).

џ

Enter the menu with a long press of the Menu button (3). 

џ

One short press of the Menu button (3) opens a menu item.

Smooth digital zoom

    – by pressing the UP (4) / DOWN (2) buttons and changing the digital zoom value from 1.0 

to 4.0. The increment size of the digital zoom is 0.1.

Brightness

    – by pressing the UP (4) / DOWN (2) buttons and changing the display brightness value from 00 to 

20.

Note. 

Current magnification is calculated as the product of the base magnification and the smooth digital zoom 

ratio. Example: where the basic device magnification is 3.0x and the smooth digital zoom ratio is x1.7, the actual 

magnification is 5,1х (3,0*1,7). The next time the device is turned on, the image is projected onto the display with 
the brightness and contrast settings saved from the previous power off.

Contrast

    – by pressing the UP (4) / DOWN (2) buttons and changing the display contrast value from 00 to 20.

Stadiametric rangefinder

    –

 

press the UP (4) / DOWN (2) buttons to change the position of the markings for 

determining  the  distance  of  the  object  being  observed  (see  Section  16  for  further  information  on  the 
rangefinder).

To exit the menu, press and hold down the Menu button (3), or wait 10 seconds for automatic selection.
The initial smooth digital zoom factor displayed is equal to x1.0 if the discrete zoom is inactive, x2.0 if is 2x, and 

x4.0 if 4x.

Mode

 

Selection of observation mode The thermal imager has three automatic operating modes. 

Each of these modes includes an optimum combination of parameters (brightness, contrast, 

intensity etc.) for ensuring the best image quality under any given observation conditions. 

џ

Press and hold the Menu button

 

(3) to enter the menu.

џ

Select the    ‘Mode’ option.

Forest

    – 

Low Contrast Mode This is the optimum mode for observing wildlife against a 

background of vegetation.

Mountains/Rocks

    – 

High Contrast Mode This is the optimum mode for observing wildlife 

against a background of rocks, and soil in an upland situation.

Identification  Mode

      – 

A  universal  mode  for  application  under  various  observation 

conditions.

џ

A short press of the Menu button (3) confirms the selection. 

џ

Select one of the settings described below with the UP (4) / DOWN (2) buttons.

џ

A short press of the Menu button (3) opens the menu.

Icon 
brightness

 

Adjusting icon brightness.

џ

Press and hold the Menu button (3) to enter the menu.

џ

Select the

  

  'Icon Brightness' option.

џ

A short press of the Menu button (3) opens the submenu.

џ

Select the brightness level of the pictograms with the UP (4) / DOWN (2) buttons.

џ

A short press of the Menu button (3) confirms the selection.

General 
Settings

 

This menu item allows you to program the following settings

Choose Language

џ

Enter the 'Language' submenu

 

   with a short press of the Menu button (3). 

џ

Confirm your selection with a short press of the Menu button (3).

џ

To save your choice and exit the submenu, press and hold down the Menu button (3). 

џ

Select  one  of  the  available  interface  languages  (English,  French,  German,  Spanish  or 

Russian) with the UP (4) / DOWN (2) buttons. 

Language

 

Composition and description of the menu

4

Содержание AXION KEY X?22

Страница 1: ...AXION KEY Thermal Imaging Monoculars Operating Instructions English Fran ais Deutsch Espa ol Italiano...

Страница 2: ...s Imageurs Thermiques AXION KEY 8 14 Fran ais Mode d emploi W rmebildkameras AXION KEY 15 21 Deutsch Bedienungsanleitung Generador de im genes t rmico AXION KEY 22 28 Espa ol Instrucciones de uso Term...

Страница 3: ...rsionoftheUser sManualmaybefoundonthewebsitewww pulsar vision com AXION KEY monoculars can be used for night time hunting observation and terrain orientation and carrying out rescueoperations AXION KE...

Страница 4: ...PS3 Lithium ion Battery Pack which enables the thermal imager to be used for up to 3 hours Thebatteryshouldbechargedbeforefirstuse Connect the mains charger 16 to the mains power supply Point A on the...

Страница 5: ...e devicepoweringoff The device will switch to operation from the external power source while the APS3 battery will be gradually recharged Attachtheexternalpowersourcetothedevice sUSBconnector 8 Fig 1...

Страница 6: ...vice is turned on the image is projected onto the display with thebrightnessandcontrastsettingssavedfromthepreviouspoweroff Contrast bypressingtheUP 4 DOWN 2 buttonsandchangingthedisplaycontrastvaluef...

Страница 7: ...rntothefactorypixelmapand NO ifyoudonot DeletethedefectivepixelwithashortpressoftheOn CalibrationONbutton 5 fixed cross that is required to facilitate a search for the defective pixel and to align the...

Страница 8: ...f When the device is switched on press and hold the ON button 5 The display will disappear and the message Displayoff willappear WhentheONbutton 5 isheld thedisplaywillshow Displayoff andacountdown DI...

Страница 9: ...e requirements of European standard EN 55032 2015 Class A Caution Operating this product in a residential area may cause radio interference Malfunction Thermal imager does not power up Does not operat...

Отзывы: