background image

www.pulsar.pl   

 

 

 

AWZ333 

 

 

 

 

 

 

 
 

 

Features: 

 

 

 

13,8VDC/3A uninterrupted supply  

 

fitting battery: 17Ah/12V 

 

mains supply 230VAC 

 

linear voltage regulator 

 

output voltage control 

 

dynamic battery test 

 

battery electrical continuity control 

 

battery voltage control 

 

battery fuse status control 

 

battery charge and maintenance control 

 

deep discharge battery protection (UVP)  

 

battery output protection against short-circuit 

         and reverse polarity connection 

 

battery charging current 0,4A/0,9A

 

jumper 

selectable

  

 

START facility for manual battery 
connection 

 

 

 

STOP facility for manual disconnection during 
battery-assisted operation 

 

LED indication 

 

acoustic indication 

 

BS technical output of AC power

 

collapse 

 

adjustable times indicating AC power failure 

 

AW technical output indicating PSU and 
battery failure 

 

protections: 

 

SCP short-circuit protection 

 

OLP overload protection 

 

OHP overheat protection 

 

over voltage protection 

 

surge protection 

 

against sabotage 

 

warranty – 5 year from the production date 

 
CONTENTS: 
1. Technical description. 

1.1 General description 
1.2 Principle of operation 
1.3 Block diagram 
1.4 Description of PSU components and connectors 
1.5 Specifications 

2. Installation. 

2.1 Requirements 
2.2 Installation procedure 

3. Operating status indication. 

3.1 LED indication 
3.2 Acoustic indication 
3.3 Technical outputs

 

4. Operation and use. 

4.1 Launching the PSU from a battery 
4.2 Disconnection of a discharged battery 
4.3 Dynamic battery test 
4.4 Battery charging current limitation 
4.5 Battery-assisted operation – standby time 
4.6 PSU overload 

5. Maintenance 

 

 
1. Technical description. 
 

1.1 General description 

A buffer PSU is intended for an uninterrupted supply to alarm system devices requiring stabilized voltage of 

12V/DC (+/-15%)

. A linear stabilizing system, which has been used in the unit, provides voltage with a lower level 

of noise and a quicker response to interference when compared to a switched-mode regulator. During buffer 
operation, he PSU provides voltage of 

Uout = 12,8V ÷ 13,8V DC

, with current capacity:  

 
 

 

1. Output current 3A (without a battery) 

 

2. Output current 2,6A + 0,4A battery charge 

    3. Output current 2,1A + 0,9A battery charge 

 

Total current of the rec battery: 3 max.

 

 
 

Содержание AWZ 333

Страница 1: ...AWZ 333 v 2 1 AWZ 13 8V 3A 17Ah LM Linear Buffer Power Supply Unit EN Edition 4 from 16 09 2013 Supercedes the edition 3 from 24 02 2012...

Страница 2: ...1 Technical description 1 1 General description 1 2 Principle of operation 1 3 Block diagram 1 4 Description of PSU components and connectors 1 5 Specifications 2 Installation 2 1 Requirements 2 2 In...

Страница 3: ...tion of the 230V mains supply the PSU automatically charges up and preserves the battery PSU operating status is indicated by LEDs on the faceplate red LED failure indication additionally failure stat...

Страница 4: ...upply output of the battery BAT red BAT black 7 RED DIODE LED indication 8 GREEN DIODE LED indication 9 CHARGE pin 10 AC AC power connector 11 Connectors TAMPER contacts of the sabotage protection swi...

Страница 5: ...he view of the PSU 1 5 Specifications electrical specifications tab 3 mechanical specifications tab 4 operation safety tab 5 operating specifications tab 6 Uwy f Io diagram Fig 4 Electrical specificat...

Страница 6: ...level 0V microswitch NC contacts enclosure closed 0 5A 50V DC max LED indication LEDs AC DC power status failure Acoustic indication piezoelectric indicator 75dB 0 3m ON OFF function F1 fuse F 5A F2 f...

Страница 7: ...iate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure Before installation make sure that the voltage in the 230V power supply circuit...

Страница 8: ...8mm clamp following the procedure according to Fig 5 put the battery into the enclosure lead the clamp through the left A hole lead the clamp over the up side of the battery lead the clamp through th...

Страница 9: ...cause disconnect the load and connect after 30 60 s 4 too high output voltage Uout 14 5V damaged voltage regulator wrong setting of the P1 potentiometer check the setting of the P1 potentiometer 5 PSU...

Страница 10: ...g the PSU from a battery push the START button on the device s board and hold for 5 seconds Finishing the battery assisted operation push the STOP button on the device s board and hold for 2 seconds T...

Страница 11: ...should be limited Characteristics for a 17Ah 12V SLA for grade 1 12h current Id 1 4A 4 6 PSU overload The PSU is equipped with an output protection due to a PTC polymer fuse If the load of the PSU exc...

Страница 12: ...s to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out a...

Отзывы: