3. Assembling instructions:

 

 

 

The ARAD4 enclosure can be mounted in two ways: 

1.

 

Mounting without the ARAS450 rails, no extension slide, the front part is the load-bearing part of the enclosure. 
This method of installation is dedicated for economic versions with a load capacity of up to 5 kg. 

 

 

                           

2.

 

Mounting with the ARAS450 rails - full extension slide of the RACK cabinet, rails of the ARAS450 series are the 

load-bearing part of the enclosure. Dedicated for up to 30kg load. 

             

2.1.

 

Mount cage nuts for M6 screws in the RACK cabinet, as shown in Figure below, and mount the ARAS rails 

(depending on the depth of the RACK cabinet). Make sure that the rail is correctly mounted horizontally and its 

length between the front and rear RACK profile is properly adjusted. 

 
 

 

 

 
 
 

 
 

 
 
 

 
 

 
 

 
 
 

 
 

 
 
 

 
 

 
 

 

 

 

 

 

 

 
 

 
 
 

 

Содержание ARAD4S

Страница 1: ... electronics transformers power supply units The enclosure can accommodate a 17Ah 12V battery and it features tampering protection against unwanted opening To enable leading cables into the enclosure one can buy a cable protection conduit of any length and a cable gland The conduits and the cable glands are available at the following codes 1 ARAP16P cable gland inside diameter 16 mm connection bet...

Страница 2: ...2 Dimensions of the mounting plate and the hinged plate ...

Страница 3: ...y of up to 5 kg 2 Mounting with the ARAS450 rails full extension slide of the RACK cabinet rails of the ARAS450 series are the load bearing part of the enclosure Dedicated for up to 30kg load 2 1 Mount cage nuts for M6 screws in the RACK cabinet as shown in Figure below and mount the ARAS rails depending on the depth of the RACK cabinet Make sure that the rail is correctly mounted horizontally and...

Страница 4: ...PSB PSBOC series Transformers of the following series TOR TRP TRZ Empty mounting Empty mounting Enclosed power supply Transformers Transformers plate PS PSB PSBOC series units TOR series TRP series TRZ 20 40 series The ARAW45 fan Cable glands and protection tubes Wires can be introduced in three ways a Through rubber grommets b Using the MM019 MM020 protection tubes c Using the MM019 MM020 protect...

Страница 5: ...RH max 90 Internal dimensions W x H x D 390 x 159 x 265 2 mm Materials Sheet metal DC01 1 0mm thick front panel thickness 1 5mm Rust protection Colour RAL 9005 BLACK Use inside Net weight 5 82 kg Gross weight 6 42 kg Declarations warranty CE 2 years from the production date Pulsar sp j Siedlec 150 32 744 Łapczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl...

Отзывы: