Pulsar ADOC551230 Скачать руководство пользователя страница 5

ww.pulsar.pl 

 

 

 

 

ADOC551230 

 
 

Temperature characteristics. 

 

 

 
 
 
 
 

 
 
 
 
Chart 1.  
Acceptable output current from the PSU 
depending on ambient temperature. 

 

 

Mechanical specifications (tab. 3). 

Enclosure dimensions 

159 x 97 x 38+23 [mm] (LxWxH)(+/- 2) 

Net/gross weight 

0,57kg / 0,61kg 

Connectors 

power supply Φ0,64÷1,63 
technical outputs: Φ0,41÷1,63 

Operation safety (tab.4). 

Protection class PN-EN 60950-1:2007 

I (first) 

Degree of Protection PN-EN 60529: 2002 (U) 

IP20 

Electrical strength of insulation: 
- between PSU input circuit and output circuits (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000 V/AC min. 
1500 V/AC min. 
500  V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500V/DC  

Operating specifications (tab.5). 

Operating temperature 

-10ºC...+60ºC  

Storage temperature 

-20ºC...+85ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insolation 

unacceptable 

Vibrations and impulse waves during transport 

PN-83/T-42106 

 
 

2. Installation. 
 

2.1 Requirements 
 

The buffer PSU is to be mounted by a qualified installer, holding relevant permits and licenses (applicable 

and  required  for  a  given  country)  for  230V/AC  interference  and  low-voltage  installations.  The  unit  should  be 
mounted  in  confined  spaces,  with  normal  relative  humidity  (RH=90%  maximum,  without  condensation)  and 
temperature from -10°C to +60°C. 

 
The  device  shall  be mounted  in  a metallic  enclosure  (a  cabinet,  an  intended  case).  In  order  to  fulfil  LVD 

and  EMC  requirements,  the  rules  for:  power-supply,  encasing  and  screening  shall  be  followed,  according  to 
application.  

  

 
During  normal  operation,  the  total  current  drawn  by  the  device  may  not  exceed  I=3A. 
Maximum battery charging current: 0,23A. Total current of the rec battery: 3,23A max. 

 
 

 
 

Содержание ADOC551230

Страница 1: ...ADOC551230 v 1 0 ADOC 13 8V 3A OC Enclosed buffer switch mode power supply unit with automatic operation control EN Edition 1 from 29 10 2013 Supercedes edition...

Страница 2: ...NTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure...

Страница 3: ...oltage 4 FAC AC absence technical output relay type 5 FPS output indicating DC absence PSU failure relay type 6 FLB output indicating battery low voltage relay type 7 FAC AC absence technical output O...

Страница 4: ...circuit protection SCP electronic automatic recovery Overload protection OLP 105 150 of power supply automatic recovery Battery circuit protection SCP and reverse polarity connection fuse Surge prote...

Страница 5: ...C Storage temperature 20 C 85 C Relative humidity 20 90 without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insolation unacceptable Vibrat...