Features: 

 

 

13,8VDC/3A uninterrupted supply 

 

wide range of supply voltage 88÷264VAC  

 

high efficiency 71% 

     battery charge and maintenance control 

     deep discharge battery protection (UVP) 

 

battery charging current 0,23A 

     battery output protection against short circuit 

and reverse polarity connection 

     LED indication 

     FAC technical output indicating AC power loss  

       – OC and relay type 

 

 

FPS technical output indicating PSU failure 

      – OC and relay type 

 

FLB technical output indicating battery low 
voltage  

      – OC and relay type 

 

protections: 

 

SCP short-circuit protection 

 

OVP over voltage protection 

 

surge protection  

 

OLP overload protection 

 

warranty – 5 year from the production date 

 

 

 
CONTENTS: 
1. Technical description. 

1.1 General description 
1.2 Block diagram 
1.3 Description of PSU components and connectors 
1.4 Specifications 

2. Installation. 

2.1 Requirements 
2.2 Installation procedure 

3. Operating status indication. 

3.1 LED indication of operating status 
3.2 Technical outputs

 

4. Operation and use. 

4.1 Overload or short circuit of the PSU output  
4.2. Battery-assisted operation 

 

4.3. Maintenance 

 
1. Technical description. 
 

1.1 General description 

A buffer PSU is intended for an uninterrupted supply to devices requiring stabilized voltage of 

12 V DC 

 (+/-15%).

 The PSU provides voltage of 

13,8V DC 

with current capacity

 I=3A + 0,23A battery charge

. In case of 

power decay, a battery back-up is activated immediately.  

 

 

 

 

During normal operation, the total current drawn by the receivers may not exceed I=3A. 
Maximum battery charging current: 0,23 A. Total device c battery: 3,23 A max. 

 

 

 

 

 

 

 

 

 

Содержание ADOC551230

Страница 1: ...ADOC551230 v 1 0 ADOC 13 8V 3A OC Enclosed buffer switch mode power supply unit with automatic operation control EN Edition 1 from 29 10 2013 Supercedes edition...

Страница 2: ...NTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure...

Страница 3: ...oltage 4 FAC AC absence technical output relay type 5 FPS output indicating DC absence PSU failure relay type 6 FLB output indicating battery low voltage relay type 7 FAC AC absence technical output O...

Страница 4: ...circuit protection SCP electronic automatic recovery Overload protection OLP 105 150 of power supply automatic recovery Battery circuit protection SCP and reverse polarity connection fuse Surge prote...

Страница 5: ...C Storage temperature 20 C 85 C Relative humidity 20 90 without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insolation unacceptable Vibrat...

Страница 6: ...tput connectors of the power supply positive pole is marked as V negative pole as COM 5 Connect the technical outputs to the central or other device 6 Connect the battery to proper output connectors o...

Страница 7: ...ich corresponds to a state with no DC power PSU failure FLB technical output indicating battery voltage OC type output Under normal status UBAT 11 5V the output is connected to ground L level 0V In ca...

Страница 8: ...epair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty term...

Отзывы: