Pulsar ADOC551230 Скачать руководство пользователя страница 4

ww.pulsar.pl 

 

 

 

 

ADOC551230 

 
 

 

Fig. 2. The view of the PSU. 

1.4 Specifications: 

- electrical specifications (tab.2) 
- mechanical specifications (tab.3) 
- operation safety (tab.4) 
- operating specifications (tab.5) 

 

 

     Electrical specifications (tab. 2). 

 

Mains supply 

88 ÷ 264V AC 

Current consumption 

1A@230VAC typ.  

PSU power  

51,38W max.  

Efficiency 

71% 

Output voltage 

11V÷ 13,8V DC – buffer operation 
9,5V÷13,8V DC – battery-assisted operation 

Output current 

3A + 0,23A battery charge 

with 18.2CFM fan – see chart 1

 

Voltage adjustment range 

12÷14,5V DC 

Ripple voltage 

100 mV p-p max. 

Current consumption by PSU systems 

60 mA  

Battery charging current 

0,23A 

Short-circuit protection SCP  

electronic, automatic recovery 

Overload protection OLP 

105-150% of power supply, automatic recovery

 

Battery circuit protection SCP and reverse 
polarity connection 

fuse 

Surge protection 

varistors 

Over voltage protection OVP 

15,87-18,63V  (automatic recovery) 

Deep discharge protection UVP 

U<9,5V (± 5%) – disconnection of the battery terminal 

Technical outputs: 
- FAC; output indicating AC power failure 
 
 
 
- FPS; output indicating DC absence/PSU 
failure 
 
- FLB output indicating battery low voltage 
 
 

 
- relay type: 1A@ 30VDC/50VAC, time lag: approx. 10s. 
- OC type, 50mA max., normal status: L (0V) level, failure: hi-Z 
level, time lag: 10s. 
 

- relay type: 1A@ 30VDC/50VAC, 

- OC type, 50mA max., normal status: L (0V) level, failure: hi-Z level  
 

- relay type: 1A@ 30VDC/50VAC, 

- OC type, 50mA max., normal status: (U

BAT

 >11,5V): 

 L (0V) level, 
 failure: (U

BAT

 <11,5V): hi-Z level 

 
 
 
 

Содержание ADOC551230

Страница 1: ...ADOC551230 v 1 0 ADOC 13 8V 3A OC Enclosed buffer switch mode power supply unit with automatic operation control EN Edition 1 from 29 10 2013 Supercedes edition...

Страница 2: ...NTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure...

Страница 3: ...oltage 4 FAC AC absence technical output relay type 5 FPS output indicating DC absence PSU failure relay type 6 FLB output indicating battery low voltage relay type 7 FAC AC absence technical output O...

Страница 4: ...circuit protection SCP electronic automatic recovery Overload protection OLP 105 150 of power supply automatic recovery Battery circuit protection SCP and reverse polarity connection fuse Surge prote...

Страница 5: ...C Storage temperature 20 C 85 C Relative humidity 20 90 without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insolation unacceptable Vibrat...

Страница 6: ...tput connectors of the power supply positive pole is marked as V negative pole as COM 5 Connect the technical outputs to the central or other device 6 Connect the battery to proper output connectors o...

Страница 7: ...ich corresponds to a state with no DC power PSU failure FLB technical output indicating battery voltage OC type output Under normal status UBAT 11 5V the output is connected to ground L level 0V In ca...

Страница 8: ...epair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty term...

Отзывы: