![Pulsar Measurement IMP Lite Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/pulsar-measurement/imp-lite/imp-lite_instruction-manual_1625416017.webp)
PULSAR MEASUREMENT
17
Button Functions
There are 4 push buttons located under the display. Their name and
functions are as follows:
How to Access Program Mode
To access the
Program mode,
press the “
ESC
” and “
Enter
” button
simultaneously, where upon the display will show
PASS
on the LCD display
briefly, to prompt you to enter the password, the display will now show
0000
, and the left-hand digit will flash.
By using the UP and DOWN keys to increment or decrement the digit, and
the ENTER key to shift the flashing digit to the next position. Assuming the
passcode is the default 1997, you should then enter this.
The ESC key can be used to go back to the previous digit. Finally, when you
have selected all digits pressing the ENTER key again will input the selected
pass code to the IMP Lite, if successful the display will show APP
(Application). If, however you input the wrong pass code the IMP Lite
LCD
display will show Fail for 2 seconds and will revert to run mode.
BUTTON
RUN MODE
PROGRAM MODE
ESC
Displays details of unit
Serial No. and Software
Version
Used to Navigate out of the
Menu System and return to
Run Mode. Also used to Cancel
a Parameter Value entered in
error.
UP
Displays Current
Temperature
Used for Navigating around
Menu System and Increasing
Menu Option Values.
DOWN
Displays Current Echo
Strength (dB’s)
Used for Navigating around
Menu System and Decreasing
Menu Option Values.
ENTER
Displays current mA output
Used to confirm an action such
as entering a Menu Option or
Enter a Parameter Value.