  Connect a vacuum pump to the top fitting of the fluid fill device.  Open BOTH 

valves  on the device. 

  Place the lower fill tube into the container of the barrier fluid 

  Using the vacuum function, use the hand pump to draw several ounces of fluid up 

into  the fill device. 

  Close both valves on the fill device 

  Remove the hose and fitting from the container, and connect the fluid fill device to 

the inlet fitting on the pump head (the fitting with the needle valve). 

  Open the fill valve (needle valve) on the pump, and then open the two plastic 

valves on the fluid fill device. 

  Switch the hand pump to the pressure function, and apply a maximum of 15 psi of 

pressure to the fluid in the chamber.  Once pressure is achieved, close the TOP 
valve and disconnect the hand pump.  There is now pressure pushing the barrier 
fluid into the leak detection system. 

  Move the hand pump to the outlet side of the system, switch it to the vacuum 

function, and continue with the filling process as outlined in the main document. 

Содержание PULSAlarm PulsaPro

Страница 1: ...UL 14 0118X Ex d IIB T5 Gb Ex tb IIIC T100 C Db IP66 Bulletin IOM PUL 1007 Rev E THIS DOCUMENT CONTAINS CHARACTERISTICS CONTROLLED BY U L FILE E186527 CHANGES REQUIRE AGENCY APPROVAL PULSAlarm LEAK DE...

Страница 2: ...ation of the original parts by Pulsafeeder personnel Parts returned for warranty considerations which are good will be sent back freight collect Any field modifications will void the warranty Out of w...

Страница 3: ...this document are subject to change without notice Trademarks Pulsa Series and PULSAlarm are registered trademarks of Pulsafeeder Inc Revision History Revision Implemented By Revision Date Approved B...

Страница 4: ...9 5 1PULSAlarm ReagentHead 10 5 2PULSAlarm LeakDetection Diaphragm 10 5 3DiaphragmConstruction 11 6 0 Electrical 12 7 0 Setup for Pressure 13 8 0 Pressure fill chamber 17 9 0 Maintenance 19 9 1Switch...

Страница 5: ...IC SHOCK Notes are general information meant to make operating the equipment easier For information on overall pump operation and maintenance refer to the Installation Operation and Maintenance manual...

Страница 6: ...rds in force and cannot under any circumstances take the place of plant standard or additional regulations including any which are not legally enforceable which have been issued with the scope of ensu...

Страница 7: ...should be taken when installing conduit to protect against fluid vapor entry In accordance with any applicable codes provide sealed entries and conduit drains near the point of entry as required For...

Страница 8: ...I Protection Methods flameproof enclosure III Gas Group IV Equipment Category IV Temperature Code or Temperature Rating max surface temp T85 V Combustible Dust Environment V Equipment Protection Level...

Страница 9: ...iaphragm that will then be transferred outwards by the barrier fluid This fluid will create pressure against the pressure switch This switch has a trip point of 20 psi 1 37 bar When this pressure is r...

Страница 10: ...ate metal spacer ring The space between the diaphragms is sealed so that the diaphragm functions as does a standard single diaphragm For the pressure system the space between the diaphragms is filled...

Страница 11: ...ruction The adhesive rings aid in assembly and are not present for sealing purposes Capillary tube Process side PTFE layer Adhesive ring Support ring Hydraulic side PTFE layer Adhesive ring Figure 2 d...

Страница 12: ...ker and attached to the PULSAlarm enclosure is adequate to satisfy this requirement The switch is the SPDT single pole double throw type and can therefore be connected to either open or to close upon...

Страница 13: ...dia is used it must be compatible with construction materials The system will require proper setup after maintenance or repairs see the following page for the proper procedure Figure 5 pressure system...

Страница 14: ...2 Remove the pressure gauge from the housing body and replace it with a straight tubing adaptor fitting This will be referred to in this document as the outlet side Figure 6 fitting for priming outle...

Страница 15: ...the plug into the needle valve to seal the system inlet 7 9 Allow vacuum to remain on the outlet side of the system for approx 2 3 minutes this will aid in the evacuation of excess fluid Once complet...

Страница 16: ...ark on the tube can assist in observing this process visually Once the liquid in the tube no longer rises the evacuation should be complete 7 18 After the startup period remove the tubing and connecti...

Страница 17: ...m readily available fittings that allow the barrier fluid to be fed under pressure to the inlet of the system Users may wish to fabricate a device based upon this sketch which will aid in the setup of...

Страница 18: ...et fitting on the pump head the fitting with the needle valve Open the fill valve needle valve on the pump and then open the two plastic valves on the fluid fill device Switch the hand pump to the pre...

Страница 19: ...next section 5 Repeat steps 3 and 4 above until the required setpoint as attained 6 Tighten the switch locking ring and replace the switch enclosure cover 7 Reconnect the alarm circuit to the switch U...

Страница 20: ...azardous materials 4 Place a suitable container underneath the pump head to catch any liquid leakage 5 Disconnect process piping and drain any process liquid following material safety precautions 6 Re...

Страница 21: ...ent head bolts and tighten in an alternating pattern to ensure an even seating force Torque to the values recommended in the Installation Operation and Maintenance manual appropriate to the pump 3 App...

Страница 22: ...A unit of IDEX Corporation 2883 Brighton Henrietta Town Line Road Rochester NY 14623 1 585 292 8000 pulsa com pulsa idexcorp com PULSAlarm LEAK DETECTION...

Отзывы: