3. Check feeders coordinate
Checking purpose: make nozzle locate in the middle of component
between left and right.
Click
―main menu‖ – ―Unit manager‖, click the number of checked feeder,
click
, the nuzzle will move to the feeder, click
and
, check whether the nuzzle locates in the middle of component.
If not, click
and
, then click
, click
again, the nuzzle wiil
move the new coordinate, check again to confirm the position. Click
after adjusted.
check pick- Ysteps
Checking purpose
:
make nozzle locate in the middle of component
between before and after.
Select any a feeder number, click
, then click
to push a
component, coil the skin manually. Then copy the data of Ysteps.
Содержание MT-60
Страница 23: ......