59
PTZ ON IP NETWORK
This model currently supports various PTZ control methods, including RS232, RS485, IR remote control, HTTP
CGI, and TCP protocol.
The following is the detailed description about HTTP CGI and TCP Protocol control methods.
1.
TCP Protocol Method
This model implements TCP server inside, there is a port configurated by Web for receiving the connection from
TCP client,the TCP port number is 5678. Once connection between client and server set up, the client will send PTZ
command to server,the server then parse and execute PTZ command.
PTZ command format is based on VISCA Protocol to define, details as below:
Command
Function
Command Packet
Comments
Zoom
Stop
81 01 04 07 00 FF
Tele(Standard)
81 01 04 07 02 FF
Wide(Standard)
81 01 04 07 03 FF
Tele(Variable)
81 01 04 07 2P FF
P = 0(low speed) - 7(high speed)
Wide(Variable)
81 01 04 07 3P FF
Focus
Stop
81 01 04 08 00 FF
Far(Standard)
81 01 04 08 02 FF
Near(Standard)
81 01 04 08 03 FF
Far(Variable)
81 01 04 08 2P FF
P = 0(low speed) - 7(high speed)
Near(Variable)
81 01 04 08 3P FF
Auto Focus
81 01 04 38 02 FF
AF On/Off
Manual Focus
81 01 04 38 03 FF
Auto/Manual
81 01 04 38 10 FF
Pan & tilt
Up
81 01 06 01 VV WW 03 01 FF
VV: Pan speed 0x01 (low speed) to 0x18
(high speed)
WW: Tilt speed 0x01 (low speed) to 0x14
(high speed)
Down
81 01 06 01 VV WW 03 02 FF
Left
81 01 06 01 VV WW 01 03 FF
Right
81 01 06 01 VV WW 02 03 FF
UpLeft
81 01 06 01 VV WW 01 01 FF
UpRight
81 01 06 01 VV WW 02 01 FF
DownLeft
81 01 06 01 VV WW 01 02 FF
DownRight
81 01 06 01 VV WW 02 02 FF
Stop
81 01 06 01 VV WW 03 03 FF
Содержание 20X-IP
Страница 1: ...PTZ Optics 20X IP User Manual V3 1 1 English...
Страница 6: ...5 Quick Start Step1 Please check connections are correct before starting...
Страница 14: ...13 USE IR Remote Controller...
Страница 18: ......
Страница 20: ...19 VISCA Network Configuration...
Страница 34: ...33 Menu Setting...
Страница 42: ...41 Click config then go to below...
Страница 58: ...57 Method 2 Open upgrade_En exe change IP and click Set...
Страница 62: ...61 action including posset poscall position number 0 89 100 254...