![PTN D-3001 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/ptn/d-3001/d-3001_user-manual_1623360012.webp)
Digital Conference System (Controlled by D-3001)
8
Note :
1)
In off-line state, the only operation unit is the chairman unit with ID A001.
2)
An y changes of parameter settings in different menus should be confirmed by the
“Enter” button and then it will exit the present menu. The “Exit” button is used to
exit the present menu without saving present settings, except in menu
“
ID Setting,
Select First ID
”, “Restore to
Factory Setting
” and “
Language Selection
”.
2.3.1 D-3001 Initialization
Press the Power button to turn on the D-3001, and then the LCD screen will show the
initialization information, showed as below:
Figure 2-7 D-3001 Initialization
After the initialization, the LCD screen will display related information, including menu,
speech capacity and speech mode shown as follow:
Figure 2-8 Initialization Finished
2.3.2 Settings after Initialization
After initializing, press
Enter
button to enter into the main menu, and Use Up and Down
button to switch among the options .
After the initialization, you need to set the MIC
’s value (live delegate microphones) and
Mode value (speech mode) for the conference.
MIC and Mode are to limit the discussion units. MIC determines the capacity of live
discussion units (total number of the ones who are able to hold a speech synchronously
(exclude chairman units), we just call it
“speech capacity” in the following content). And
Mode determines what the discussion unit can do when reaches at the maximum
speech capacity or not.
The following content will show you the detailed information about speech capacity and
speech mode.
1)
MIC Value Setting
Use Up and Down button to switch to the option
“MIC”.
Press Enter button to enter into speech number setting interface.