background image

 

www.tpcdental.com 

Mirage Model 4000 
Mirage Model 3000 

Hydraulic Patient Chair 

 

Installation, Operation & User Manual  

TPC 

851 S. Lawson St. 

City of Industry, CA 91748 

 Phone 626-810-4337 Fax 626-810-4245 

 

REV. 1-1-13

Содержание Mirage 3000

Страница 1: ...ww tpcdental com Mirage Model 4000 Mirage Model 3000 Hydraulic Patient Chair Installation Operation User Manual TPC 851 S Lawson St City of Industry CA 91748 Phone 626 810 4337 Fax 626 810 4245 REV 1 1 13 ...

Страница 2: ...s Patient chairs that are used for swing mount delivery are pre plumed with tubing to make your installation process easier If your installation requires the installation of a touch pad DO NOT install the upholstery seat cushion till after your touch pad is installed Failure to do so will result in double work If at any time you have questions regarding your installation please don t hesitate to c...

Страница 3: ...structions 5 Installation and coordination 6 Operation instructions 11 Overview of foot controls 12 Overview of touchpad controls 13 Features 14 Main PCB Board 16 Wiring Schematic 1 17 Adjusting main flow control block 19 Replacement Parts List 20 CLEANING DISINFECTING GUIDE 24 Warranty 25 TROUBLE SHOOTING GUIDE 26 ...

Страница 4: ...anufacture This label is located on the front lower left cover under the seat cushion The dental chair is marked with a caution symbol This label is located on the front of the dental chair base next to the main power switch The dental chair is marked with a Risk Class symbol This label is located on the front of the dental chair base next to the main power switch The dental chair is marked with a...

Страница 5: ...tall the dental chair Do not turn the carton on its side as oil will drain out of the tank reservoir Damage may occur if the chair is tipped over Remove all the staples securing the carton to pallet or cut the carton just above the staple line and remove Carton Figure 1 When lifting the dental chair use extreme caution The chair weight is approximately 310 LBS Always use at least two people when a...

Страница 6: ... in a safe place for future use Once the bolts are removed your backrest bracket should look similar to the one shown to the right Slide the backrest bracket into place Make sure when you slide the bracket into place you don t damage the plastic backrest cover by forcing it or twisting it You may loosen the screws that attach the backrest cover to the plate if you would like ...

Страница 7: ...krest bracket is in place the 4 bolt holes should be aligned Insert and tighten the 4 bolts with the lock washers in place Be sure not to over tighten the bolts Use the lock washer and bolts from step 1 to fasten the bracket in place ...

Страница 8: ... slide up and down with little resistance in the backrest bracket 4 Once the space is adjusted remove the bolts with the nuts still attached and try to keep the spacing the same 5 Place the bolts into the backrest as shown in figure 3 6 Slide the upholstery into the backrest bracket Press gently on the seat back cushion side so that all four bolts align properly within the backrest bracket Once al...

Страница 9: ...e s bracket shown in figure 2 to the upholstery 4 Mount the s bracket as shown in figure 3 5 Attach the two Allen screws included to the chair seat cushion frame shown in figure 3 Incorrect Mounting the S bracket this way will damage the upholstery frame Damage will occur Notice that the bracket is hanging over the upholstery Correct Notice that the S bracket is flush with the end of the upholster...

Страница 10: ...ight 2 locate the Allen screws lock washer and washers shown in figure 2 3 Once the bracket is securely in place you may fasten the toe of the upholstery to the frame as shown in figure 3 4 Attach the headrest upholstery to the headrest stem as shown in figure 4 Be sure to use the counter sunk Phillip head screws shown in figure 5 Don t over tighten the screws Figure 1 Figure 1 1 Figure 2 Figure 3...

Страница 11: ...11 www tpcdental com Mirage Model 4000 operation instructions Please take time out to read the features and to familiarize yourself with the chair ...

Страница 12: ...nstalled but can be changed at your convenience as shown below Set backrest angle and seat height to desired position using the foot control Press and hold the preset position 1 or 2 on foot control You will hear an initial tone when the button is pressed After about 5 seconds you will hear a confirm tone Now that preset position is programmed 5 Automatic Return Momentarily press 0 switch on foot ...

Страница 13: ... 4 Adjusting Preset The preset mode is factory installed but can be changed at your convenience as shown below Set backrest angle and seat height to desired position using the touch pad Press preset position 1 2 or 3 on touch pad and hold down You will hear an initial tone After about 5 seconds you will hear a confirm tone Now that preset position is programmed 5 Automatic Return Momentarily press...

Страница 14: ... chair Pull lever to the right to release lock This allows chair to swivel to the right 30 degrees and to the left 30 degrees To lock swivel pull lever to the left 9 Headrest Adjustments Height of headrest can be adjusted simply by pulling headrest up or down due to friction mount incorporated in backrest Angle of articulating headrest can be changed by releasing slide bar on headrest back 10 Auto...

Страница 15: ...in PCB board to program Reset the Slide Switch on PCB to Normal Use the touch pad or foot control to move the chair up and then use the lift down on the touch pad or foot control to verify that the new limit is set Seat Height Limit Using the manual controls raise the seat height fully At the physical top of travel the motor will continue to run but upward motion will stop oil bypass channel has o...

Страница 16: ...16 www tpcdental com Main PCB Board ...

Страница 17: ...17 www tpcdental com Wiring schematic 1 ...

Страница 18: ...18 www tpcdental com Wiring schematic ...

Страница 19: ... Base down Flow Control TV3 Back up flow control TV4 Back down flow control When adjusting the flow control valves counter clockwise turns will open increase flow Turning the valve clockwise will close the valve and decrease the flow Don t open or close a flow control valve completely Its best to make adjustments in quarter turn rotations only ...

Страница 20: ...10A 4 Back Flange M4000 011A 5 Cushion Frame M4000 012A 6 U Bracket M4000 022 7 Backrest Frame M4000 025 8 Arm Rest flange 1 M4000 028 9 Arm Rest Flange 2 M4000 28A 10 Arm Rest Bracket L M4000 029 11 Arm Rest Bracket R M4000 029A 12 Cross Support M4000 041 13 Arm Rest M4000 042 14 Cross Support Bolt M4000 043 15 5 DVW HDULQJ 04000 12ZZ 16 6HDW UDPH 5ROOHU M4000 1215 16 ...

Страница 21: ...026 5 Head Rest M4000 027 6 Rear Flange Cover M4000 030 7 L Side Cover M4000 031 8 R Side Cover M4000 031A 9 Rear L side Cover M4000 032 10 Rear R Side Cover M4000 032A 11 Backrest Cover M4000 033 12 Lower L Cover M4000 034 13 Lower R Cover M4000 034A 14 Head Rest Stem M4000 01 15 Cast Base M4000 A 16 Cantilever Cast M4000 B 17 Back Rest Base M4000 C ...

Страница 22: ... 1 Cast Base M4000 001 2 R Arm Support M4000 002 3 L Arm Support M4000 003 4 Arm M4000 006 5 Bottom Base Cover M4000 016 6 Bottom Pump T M4000 017 7 Top Pump Arm M4000 018 8 Top Pump T M4000 019 9 Connecting Rod M4000 036 10 Hydraulic Pump M4000 HYD ...

Страница 23: ...0 007 4 Rotator Insert M4000 020 5 Break Clamp M4000 021 6 Cantilever Rod M4000 035 7 Cantilever Pins M4000 037 8 Break Clamp Rod M4000 038 9 Break Clamp Arm M4000 039 10 Hydraulic Pin M4000 040 11 Bracket Base M4000 044 12 Insert Base Connector M4000 045 13 Rollers Seat Pan M4000 RSP 14 Hydraulic Piston M4000 HYD ...

Страница 24: ... disinfectant to soak in or dry on the surface wipe off with soap and water PLEASE KEEP LIQUIDS AWAY FROM ELECTRICAL CONNECTIONS Most electrical control switches ARE NOT hermetically sealed When a switch gets wet it can self activate or perhaps short out and damage other system components Keep switches dry Avoid costly equipment damage or failure Avoid downtime by following these guidelines Please...

Страница 25: ...freight carrier must be initiated at the time the damaged items are received The claim is the responsibility of the customer We are improving our products on a continuous basis We reserve the right to make modifications without the need for prior notification and are not obliged to modify previously manufactured items Main hydraulic pumps and hydraulic parts are covered under the 5 year warranty M...

Страница 26: ...rational mode Put chair in normal operation mode Change SW1 on Main PCB When I auto return the chair with button 0 the chair goes down and then raises about 3 once its down Safety switch is being tripped Check safety switch and area around chair base My chair is on but there is no control out of the touch pad Touch pad is not connected Touch pad is burnt out Connect touch pad Replace touch pad My ...