Appendix C: Bar Code Settings
Code 128
Psion Teklogix NEO Hand-Held Computer User Manual
C
-21
Accepted Start Char
This parameter allows the user the option of using one of the two start/stop characters or
both (
$
char,
*
char,
$
and
*
char).
Check Digit Verification
Uses the specified algorithm of the option you've chosen to ensure the integrity of the
symbol data before transmitting. If the data does not contain that algorithm, the data is not
transmitted. The available options are:
Disabled, MOD 43 Check, French CIP
, or
Italian CIP
.
Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.
Minimum Length
Minimum lengths for the bar code can be set from
0
to
255
. The length of a code refers to
the number of characters (i.e., human readable characters), including check digit(s).
Length Restriction
Refer to “Length Restriction” on page C-7 for details.
Add/Remove Data
Refer to “Add/Remove Data” on page C-8 for details.
C.2.4
Code 128
Enable
Setting this parameter to
on
enables
Code 128
.
GS1-128
GS1-128
is the GS1 implementation of the Code 128 barcode specification. The former
correct name was UCC/EAN-128.
Note: French CIP (French pharmaceutical) is only used with bar codes containing
7 characters.
Italian CIP (Italian pharmaceutical) is also known as Code 32. It is transmitted as a
standard Code 39 if checksum is not validated.